SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:mdh-61422"
 

Sökning: id:"swepub:oai:DiVA.org:mdh-61422" > Experimental study ...

Experimental study on a multi-evaporator mutual defrosting system for air source heat pumps

Rong, X. (författare)
CSCEC Green Construction Engineering Research Center, Chengdu, 610041, China
Long, W. (författare)
CSCEC Green Construction Engineering Research Center, Chengdu, 610041, China
Jia, J. (författare)
CSCEC Green Construction Engineering Research Center, Chengdu, 610041, China
visa fler...
Liu, L. (författare)
CSCEC Green Construction Engineering Research Center, Chengdu, 610041, China
Si, P. (författare)
CSCEC Green Construction Engineering Research Center, Chengdu, 610041, China
Shi, L. (författare)
CSCEC Green Construction Engineering Research Center, Chengdu, 610041, China
Yan, Jinyue, 1959- (författare)
Mälardalens universitet,Framtidens energi
Liu, B. (författare)
CSCEC Green Construction Engineering Research Center, Chengdu, 610041, China
Zhao, M. (författare)
Guangdong New Energy Technology Development Co. Ltd., Guangdong, 511356, China
visa färre...
 (creator_code:org_t)
Elsevier Ltd, 2023
2023
Engelska.
Ingår i: Applied Energy. - : Elsevier Ltd. - 0306-2619 .- 1872-9118. ; 332
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Air source heat pumps (ASHPs) are prone to frost when heating in a low-temperature and high-humidity environment, which deteriorates the heating performance of the unit. In this study, a new multi-evaporator mutual defrosting (MEMD) system was proposed to overcome the disadvantages of traditional defrosting methods: intermittent heating and inefficient defrosting. To validate the performance of the proposed defrosting technology, comparative tests were conducted in various outdoor environmental conditions. The experimental results showed that the MEMD system could continuously heat water during the defrosting period. In five experimental conditions, the MEMD system exhibited a lower water temperature drop range (2.1–2.8 °C) than that of a traditional reverse-cycle defrosting (RCD) system (6.0–7.3 °C). Due to the effective utilization of heat production during the heating period, the effective heat power (qe) of the unit increased by 0.7–1.4 kW, and the heat loss coefficient (HLC) of frosting and defrosting increased by an average of 6 % in the five experimental conditions, effectively reducing the heating capacity loss of the unit caused by defrosting. While defrosting, the MEMD system was able to utilize the remaining evaporators to absorb heat from the air and then deliver it to the defrosting evaporator. The equivalent defrosting energy efficiency (COPd) of the MEMD system was 17.5 % greater than that of the RCD system on average. During the heating and defrosting cycle, the energy saved when defrosting could increase the cycle coefficient of performance (CCOP) of heating by 3.7 %. 

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

Air source heat pump
Defrosting
Energy efficiency
Heating
Air source heat pumps
Environmental technology
Evaporators
Heat losses
Pumps
Temperature
Air-source heat pumps
Defrosting systems
Experimental conditions
Heating performance
High-humidity environment
Intermittent heating
Low-high
Lows-temperatures
Temperature/ humidities

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy