SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:mdh-62486"
 

Sökning: id:"swepub:oai:DiVA.org:mdh-62486" > Influence of the tr...

Influence of the transient operation of a large-scale thermal energy storage system on the flexibility provided by CHP plants

Zlatkovikj, Milan (författare)
Mälardalens universitet,Framtidens energi
Zaccaria, Valentina, 1989- (författare)
Mälardalens universitet,Framtidens energi
Li, Hailong, 1976- (författare)
Mälardalens universitet,Framtidens energi
 (creator_code:org_t)
Elsevier Ltd, 2023
2023
Engelska.
Ingår i: e-Prime - Advances in Electrical Engineering, Electronics and Energy. - : Elsevier Ltd. - 2772-6711. ; 4
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Among many technical options to improve the flexibility in combined heat and power (CHP) plants, thermal energy storage (TES) has attracted the most attention with its high applicability and benefit. Previous studies normally adopted a simplified approach for modelling a TES system, which assumes the optimized charged or discharged rate of heat can always be realized within the rated capacity. However, this may yield unfeasible results as the charging and discharging rates are dependent on the dynamic status of a TES, such as the state of charge (SOC) and water temperature, and the water flowrate for charging and discharging. In order to consider the transient operation of a TES, a 1D dynamic model was developed and validated against measured data from a real CHP plant. To analyze the dynamic performance of a TES, two key performance indicators (KPI), the maximum charging/discharging rate (C/D-ratemax) and the constant maximum charging/discharging rate that can be maintained constantly for one hour (CC/CD-ratemax) were employed. By doing simulations, it has been found that the CC/CD-ratemax was lower than the C/D-ratemax for most given SOCs of the studied TES. The developed model was also used to examine the optimized operation of a TES for providing flexibility. Some unfeasible results have been identified, as the optimized hourly charging/discharging rates were constrained by the CC/CD-ratemax. Therefore, it is of great importance to integrate a detailed dynamic model when optimizing the dispatch of electricity and heat for a CHP plant. 

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Energisystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Energy Systems (hsv//eng)

Nyckelord

Charging/discharging rates
Combined heat and power (CHP)
Dynamic simulation
Flexibility
State of charge (SOC)
Thermal energy storage (TES)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Zlatkovikj, Mila ...
Zaccaria, Valent ...
Li, Hailong, 197 ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Naturresurstekni ...
och Energisystem
Artiklar i publikationen
e-Prime - Advanc ...
Av lärosätet
Mälardalens universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy