SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:mdh-63503"
 

Sökning: id:"swepub:oai:DiVA.org:mdh-63503" > Capacity Fading Cha...

Capacity Fading Characteristics of Lithium Iron Phosphate Batteries Under Different Precooling Conditions

Shi, J. (författare)
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, 300134, China
Li, X. (författare)
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, 300134, China
Wang, Y. (författare)
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, 300134, China
visa fler...
Wang, Z. (författare)
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, 300134, China
Liu, S. (författare)
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, 300134, China
Li, Hailong, 1976- (författare)
Mälardalens universitet,Framtidens energi,Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, 300134, China
visa färre...
 (creator_code:org_t)
Springer Science and Business Media Deutschland GmbH, 2023
2023
Engelska.
Ingår i: Lecture Notes in Electrical Engineering, vol. 1016. - : Springer Science and Business Media Deutschland GmbH. - 9789819910267 ; , s. 1-9
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The capacity fading of lithium iron phosphate batteries is related to its internal temperature and the growth of solid electrolyte (SEI). It is an effective way by controlling its internal temperature to mitigate capacity fading. This paper discusses the impact of pre-cooling and resting time on capacity fading and the growth of SEI. Results showed that the battery capacity increased and the thickness of SEI decreased if the pre-cooling was employed. Compared to 25 °C of ambient temperature, the thickness of SEI under 5 °C of pre-cooling temperature decreased by 404 nm, 386 nm, and 502 nm for 2C, 3C, and 5C discharge rate, respectively. The internal temperature of battery could be better cooled and therefore capacity increased with the increase of resting time. At 15 °C of pre-cooling temperature, the capacity increased by 3.8% if the resting time increased from 600 s to 2400 s. Therefore, the pre-cooling method could effectively mitigate capacity fading. The conclusion obtained in this paper could provide guidance for battery thermal management. 

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

Battery thermal management
Capacity fade
LiFePO<sub>4</sub> battery
Pre-cooling

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Shi, J.
Li, X.
Wang, Y.
Wang, Z.
Liu, S.
Li, Hailong, 197 ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Energiteknik
Artiklar i publikationen
Lecture Notes in ...
Av lärosätet
Mälardalens universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy