Investigation of the surface topographical differences between the Cross Direction and the Machine Direction for newspaper and paperboard

Alam, Mohammad Anzar (författare)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013),Optical on-line measurements in industry
Thim, Jan (författare)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013),Optical on-line measurements in industry
Manuilskiy, Anatoliy (författare)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013),Optical on-line measurements in industry
visa fler...
O'Nils, Mattias (författare)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013),Optical on-line measurements in industry
Westerlind, Christina (författare)
SCA R&D Centre, Sundsvall, Sweden,Optical on-line measurements in industry
Lindgren, Johan (författare)
Iggesund Paperboard AB, Iggesund, Sweden,Optical on-line measurements in industry
Lidén, Joar (författare)
SCA Ortviken AB, Sundsvall, Sweden,Optical on-line measurements in industry
visa färre...
 (creator_code:org_t)
2011
2011
Engelska.
Ingår i: Nordic Pulp & Paper Research Journal. - 0283-2631 .- 2000-0669. ; 26:4, s. 468-475
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Paper and paperboard surface quality is constantly being improved by the industry. This improvement work deals with the essential fact that the surface topography must be measured, both in relation to offline and online measurements for the manufactured products. Most measurements relating to surface topography (especially online) are performed either in the machine direction (MD) or in the cross direction (CD). It has been the opinion of SCA Ortviken AB and Iggesund Paperboard AB that the surface topography amplitudes are almost always higher in the CD than in the MD, for their products which consist of newspaper and paperboard. This article aims to investigate the rela-tionship between the CD and the MD surface topography amplitudes for a wide range of spatial wavelength for both newspaper and paperboard. The tests and investiga-tions have been conducted using an FRT Microprof profilometer within the range 20 μm up to 8 mm, and the results confirm that the surface topography amplitudes are higher in the CD for most of the shorter spatial wavelength within this range. The results also show significant differences between measurements for different paper qualities, suggesting a requirement to investigate the relationship between the CD and the MD topography for all paper and paperboard qualities of interest for a paper or paperboard mill, before a decision is made in relation to a measurement method.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Inbäddad systemteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Embedded Systems (hsv//eng)

Nyckelord

Paper surface measurement
Roughness measurement
Surface topography
Optical measurement
spectral analysis
Cross Direction (CD)
Machine Direction (MD)
Paperboard
Newspaper

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy