Integration of an interferometric IR absorber into an epoxy membrane based CO2 detector

Ashraf, Shakeel, 1984- (författare)
Mittuniversitetet,Avdelningen för elektronikkonstruktion,Detector and Photonics
Mattsson, Claes (författare)
Mittuniversitetet,Avdelningen för elektronikkonstruktion,Detector and Photonics
Thungström, Göran (författare)
Mittuniversitetet,Avdelningen för elektronikkonstruktion,Detector and Photonics
visa fler...
Rödjegard, Henrik (författare)
SenseAir AB, Delsbo, Sweden
visa färre...
 (creator_code:org_t)
2014
2014
Engelska.
Ingår i: Journal of Instrumentation. - 1748-0221. ; 9:5, s. Art. no. C05035-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Measurements of carbon dioxide levels in the environment are commonly performedby using non-dispersive infrared technology (NDIR). Thermopile detectors are often used in NDIRsystems because of their non-cooling advantages. The infrared absorber has a major influence onthe detector responsivity. In this paper, the fabrication of a SU-8 epoxy membrane based Al/Bithermopile detector and the integration of an interferometric infrared absorber structure of wavelength around 4 µ m into the detector is reported. The membrane of thermopile detector has beenutilized as a dielectric medium in an interferometric absorption structure. By doing so, a reduction in both thermal conductance and capacitance is achieved. In the fabrication of the thermopile,metal evaporation and lift off process had been used for the deposition of serially interconnectedAl/Bi thermocouples. Serial resistance of fabricated thermopile was measured as 220 kΩ. Theresponse of fabricated thermopile detector was measured using a visible to infrared source of radiation flux 3.23 mW mm−2. The radiation incident on the detector was limited using a band passfilter of wavelength 4.26 µ m in front of the detector. A responsivity of 27.86 V mm2W−1at roomtemperature was achieved using this setup. The fabricated detector was compared to a referencedetector with a broad band absorber. From the comparison it was concluded that the integratedinterferometric absorber is functioning correctly.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

Detector modelling and simulations I (interaction of radiation with matter
interaction of photons with matter
interaction of hadrons with matter
etc); Spectrometers

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy