On the importance of controlling film architecture in detecting prostate specific antigen

Graça, Juliana Santos (författare)
Federal University of São Carlos, Center for Sciences and Technology for Sustainability, Sorocaba, SP, Brazil
Miyazaki, Celina Massumi (författare)
Federal University of São Carlos, Center for Sciences and Technology for Sustainability, Sorocaba, SP, Brazil
Shimizu, Flavio M. (författare)
University of São Paulo, São Carlos, SP, Brazil
visa fler...
Volpati, Diogo (författare)
Mittuniversitetet,Avdelningen för naturvetenskap
Mejía-Salazar, J. R. (författare)
University of São Paulo, São Carlos, SP, Brazil
Oliveira Jr, Osvaldo N. (författare)
University of São Paulo, São Carlos, SP, Brazil
Ferreira, Marystela (författare)
Federal University of São Carlos, Center for Sciences and Technology for Sustainability, Sorocaba, SP, Brazil
visa färre...
 (creator_code:org_t)
Elsevier BV, 2018
2018
Engelska.
Ingår i: Applied Surface Science. - : Elsevier BV. - 0169-4332 .- 1873-5584. ; 434, s. 1175-1182
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Immunosensors made with nanostructured films are promising for detecting cancer biomarkers, even at early stages of the disease, but this requires control of film architecture to preserve the biological activity of immobilized antibodies. In this study, we used electrochemical impedance spectroscopy (EIS) to detect Prostate Specific Antigen (PSA) with immunosensors produced with layer-by-layer (LbL) films containing anti-PSA antibodies in two distinct film architectures. The antibodies were either adsorbed from solutions in which they were free, or from solutions where they were incorporated into liposomes of dipalmitoyl phosphatidyl glycerol (DPPG). Incorporation into DPPG liposomes was confirmed with surface plasmon resonance experiments, while the importance of electrostatic interactions on the electrical response was highlighted using the Finite Difference Time-Domain Method (FDTD). The sensitivity of both architectures was sufficient to detect the threshold value to diagnose prostate cancer (ca. 4 ng mL−1). In contrast to expectation, the sensor with the antibodies incorporated into DPPG liposomes had lower sensitivity, though the range of concentrations amenable to detection increased, according to the fitting of the EIS data using the Langmuir-Freundlich adsorption model. The performance of the two film architectures was compared qualitatively by plotting the data with a multidimensional projection technique, which constitutes a generic approach for optimizing immunosensors and other types of sensors. 

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Materialteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering (hsv//eng)

Nyckelord

Electrochemical impedance spectroscopy
Finite difference time-domain method
Immunosensor
Layer-by-layer
Liposome

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy