Evaluation of a CO2 sensitive thermopile with an integrated multilayered infrared absorber by using a long path length NDIR platform

Ashraf, Shakeel, 1984- (författare)
Mittuniversitetet,Avdelningen för elektronikkonstruktion
Mattsson, Claes, 1978- (författare)
Mittuniversitetet,Avdelningen för elektronikkonstruktion
Thungström, Göran, 1960- (författare)
Mittuniversitetet,Avdelningen för elektronikkonstruktion
visa fler...
Gaynullin, B. (författare)
Research and Development Department, SenseAir AB, Delsbo
Rödjegård, H. (författare)
Research and Development Department, SenseAir AB, Delsbo
visa färre...
 (creator_code:org_t)
IEEE, 2018
2018
Engelska.
Ingår i: I2MTC 2018 - 2018 IEEE International Instrumentation and Measurement Technology Conference. - : IEEE. - 9781538622223 ; , s. 1-6
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this work, a mid-infrared-sensitive thermopile detector was evaluated for carbon dioxide gas. The thermopile has an integrated absorber structure that has more than 95% absorption for the wavelength range of 3.3-5.5 μm. For the measurement of carbon dioxide, the detector was initially assembled on a small printed circuit board holder and then installed in a long path length non-dispersive infrared platform. The measurement setup was calibrated by exposing the detector to carbon dioxide of known concentrations (from 50 ppm to 1,300 ppm) and measuring the corresponding voltage response of the detector. The measured voltage values allowed us to calculate the calibration constant for this detector. This was followed by a verification process using a concentration of 500 ppm (which was not used in the calibration) and a known value of 1,300 ppm. The verification results matched with real values, demonstrating that the sensor can be used for highly sensitive and accurate carbon dioxide measurements at concentrations from a few ppm level up to 1,300 ppm. Above this level, additional calibration is needed. 

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

Carbon dioxide gas measurement
LPL-NDIR sensor
Thermopile detector

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy