Fabrication and characterization of a SU8-epoxy membrane based thermopile detector with an integrated multilayered absorber structure for the mid-IR region

Ashraf, Shakeel, 1984- (författare)
Mittuniversitetet,Institutionen för elektronikkonstruktion
Mattsson, Claes, 1978- (författare)
Mittuniversitetet,Institutionen för elektronikkonstruktion
Thungström, Göran, 1960- (författare)
Mittuniversitetet,Institutionen för elektronikkonstruktion
 (creator_code:org_t)
2019
2019
Engelska.
Ingår i: IEEE Sensors Journal. - 1530-437X .- 1558-1748. ; 19:11, s. 4000-4007
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper reports on the fabrication and characterization of a thermopile detector with an integrated mid-infrared absorber structure. The fabricated absorber structure has shown an absorption of more than 95% in the wavelength range of 3.2 – 5.47 μm. The detector was fabricated with standard cleanroom process techniques and equipment. The serial resistance was measured at about 315 kΩ at room temperature. The photosensitivity of the detector was characterized for a signle wavelength (4.26 µm) and a band of wavelength ranging from 2.5 –5.5 µm through two different measurement setups. In the first measurement setup, the photosensitivity was estimated at 57.5 V·mm2·W-1 through a MEMS-based infrared radiation source and with an optical band-pass filter of wavelength 4.26µm. The following characterization was performed to characterise the photosensitivity of the detector in a broader wavelength range. This measurement was taken using a monochromator setup utilizing a reference photodetector for calculations of the optical power of the infrared source. The photosensitivity and the specific detectivity (D*) of the fabricated detector were measured to values of 30-92 V·W-1 and 8.0×107-2.4×108 cm·Hz1/2·W-1, respectively, in the wavelength range of 2.8 – 5 µm. The time constant was estimated to around 21 ms

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

Interfermometric absorber
Thermopile
Infrared detector
SU8 epoxy
photosensitivity
Transfer matrix theory
CO2 detection

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy