An Energy-Efficient Algorithm for Wearable Electrocardiogram Signal Processing in Ubiquitous  Healthcare Applications

Sodhro, Ali Hassan, 1986- (författare)
Sukkur IBA University, Sukkur 65200, Pakistan; University Lumiere Lyon2, Bron-69500, France,RECS
Sangaiah, Arun Kumar (författare)
Sodhro, Gul Hassan (författare)
visa fler...
Lohano, Sonia (författare)
Pirbhulal, Sandeep (författare)
visa färre...
 (creator_code:org_t)
2018-03-20
2018
Engelska.
Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 18:3, s. 923-923
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Rapid progress and emerging trends in miniaturized medical devices have enabled the un-obtrusive monitoring of physiological signals and daily activities of everyone’s life in a prominent and pervasive manner. Due to the power-constrained nature of conventional wearable sensor devices during ubiquitous sensing (US), energy-efficiency has become one of the highly demanding and debatable issues in healthcare. This paper develops a single chip-based wearable wireless electrocardiogram (ECG) monitoring system by adopting analog front end (AFE) chip model ADS1292R from Texas Instruments. The developed chip collects real-time ECG data with two adopted channels for continuous monitoring of human heart activity. Then, these two channels and the AFE are built into a right leg drive right leg drive (RLD) driver circuit with lead-off detection and medical graded test signal. Human ECG data was collected at 60 beats per minute (BPM) to 120 BPM with 60 Hz noise and considered throughout the experimental set-up. Moreover, notch filter (cutoff frequency 60 Hz), high-pass filter (cutoff frequency 0.67 Hz), and low-pass filter (cutoff frequency 100 Hz) with cut-off frequencies of 60 Hz, 0.67 Hz, and 100 Hz, respectively, were designed with bilinear transformation for rectifying the power-line noise and artifacts while extracting real-time ECG signals. Finally, a transmission power control-based energy-efficient (ETPC) algorithm is proposed, implemented on the hardware and then compared with the several conventional TPC methods. Experimental results reveal that our developed chip collects real-time ECG data efficiently, and the proposed ETPC algorithm achieves higher energy savings of 35.5% with a slightly larger packet loss ratio (PLR) as compared to conventional TPC (e.g., constant TPC, Gao’s, and Xiao’s methods).

Nyckelord

electrocardiogram (ECG) signal processing
wearable platform
noise
energy-efficiency
Filters
healthcare
ETPC
ubiquitous
beats per minute (BPM)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Sensors (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy