SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:miun-43426"
 

Sökning: id:"swepub:oai:DiVA.org:miun-43426" > Analysis of the foa...

Analysis of the foam-forming of non-woven lightweight fibrous materials using X-ray tomography

Burke, S. R. (författare)
Möbius, M. E. (författare)
Hjelt, T. (författare)
visa fler...
Ketoja, J. A. (författare)
Hutzler, S. (författare)
visa färre...
2021-01-24
2021
Engelska.
Ingår i: SN Applied Sciences. - : Springer Nature. - 2523-3963 .- 2523-3971. ; 3:2
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Abstract: Foam-forming has in the past predominantly been used to create two-dimensional sheet-like fibrous materials. Allowing the foam to drain freely and decay under gravity, rather than applying a vacuum to remove it rapidly, we can produce lightweight three-dimensional fibrous structures from cellulose fibres, of potential use for thermal and acoustic insulation. μCT scanning of the fibrous materials enable us to determine both void size distributions and also distributions of fibre orientations. Through image analysis and uniaxial compression testing, we find that the orientation of the fibres, rather than the size of the voids, determine the compressive strength of the material. The fibrous samples display a layering of the fibres perpendicular to the direction of drainage of the precursor liquid foam. This leads to an anisotropy of the compressive behaviour of the samples. Varying the initial liquid fraction of the foam allows for tuning of the compressive strength. We show an increase in over seven times can be achieved for samples of the same density (13 kg.m-3). Graphic abstract: [Figure not available: see fulltext.]. © 2021, The Author(s).

Nyckelord

Compressive strength
Fibre orientation
Foam-forming
Imaging
Lightweight fibrous materials
Materials
Natural fibres
Compression testing
Computerized tomography
Fibers
Thermal insulation
Cellulose fibres
Fibrous material
Fibrous structures
Precursor liquids
Uniaxial compression testing
Void size distribution
X-ray tomography

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy