SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:miun-9673"
 

Search: id:"swepub:oai:DiVA.org:miun-9673" > Energy Resolved X-r...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Energy Resolved X-ray Imaging as a Tool for Characterization of Paper Coating Quality

Norlin, Börje, 1967- (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013),STC
Fröjdh, Christer, 1952- (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013),STC
O'Nils, Mattias (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013)
show more...
Fröjdh, Anna, 1984- (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013)
Fröjdh, Erik, 1986- (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013),STC
Thungström, Göran (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013)
show less...
 (creator_code:org_t)
IEEE conference proceedings, 2009
2009
English.
In: IEEE Nuclear Science Symposium Conference Record 2009. - : IEEE conference proceedings. - 9781424439621 ; , s. 1703-1706
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • Energy resolved X-ray imaging can be used as a tool to analyze the variation in the chemical content of an object. In this work we have used energy resolved X-ray imaging to measure the variation in the chemical content of paper and paper coating. This is an important quality parameter for the paper industry. In order to separate the variation in coating thickness from the variation in paper thickness, energy resolution is used to separate the response of the coating from the response of the paper. The MEDIPIX2 single photon processing X-ray imaging system [1] has been used in the measurements.  The measurement results are compared to simulations with MCNP. The influence of charge sharing is discussed and the effects have been studied by comparing results from detectors with 220x220 µm2 pixels and detectors with 55x55 µm2 pixels. There is a trade-off between good spatial resolution obtained with detectors with small pixels and good energy resolution obtained with detectors with large pixels. The requirements on image quality, to achieve the resolution of coating distribution relevant for the application, are discussed.

Keyword

TECHNOLOGY
TEKNIKVETENSKAP

Publication and Content Type

ref (subject category)
kon (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view