SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:oru-33269"
 

Sökning: id:"swepub:oai:DiVA.org:oru-33269" > The No-Touch Saphen...

The No-Touch Saphenous Vein as the Preferred Second Conduit for Coronary Artery Bypass Grafting

Dreifaldt, Mats (författare)
Örebro universitet,Institutionen för hälsovetenskap och medicin,Region Örebro län,Department of Cardiovascular Surgery, Örebro University Hospital, Region Örebro County, Örebro, Sweden
Mannion, John D. (författare)
Department of Surgery, Bayhealth Medical Center, Dover DE, USA
Bodin, Lennart (författare)
Karolinska Institutet,Örebro universitet,Handelshögskolan vid Örebro Universitet
visa fler...
Olsson, Hans (författare)
Zagozdzon, Leszek (författare)
Souza, Domingos S. R. (författare)
Region Örebro län
visa färre...
 (creator_code:org_t)
Elsevier BV, 2013
2013
Engelska.
Ingår i: Annals of Thoracic Surgery. - : Elsevier BV. - 0003-4975 .- 1552-6259. ; 96:1, s. 105-111
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Injury incurred while saphenous veins are being obtained results in poor graft patency and impairs the results of coronary artery bypass grafting. A novel method of obtaining veins, the no-touch technique, has shown improved long-term saphenous vein graft patency.Methods: This randomized trial included 108 patients undergoing coronary artery bypass grafting and compared the patency of no-touch saphenous vein with that of radial artery grafts. Each patient was assigned to receive one no-touch saphenous vein and one radial artery graft to either the left or the right coronary territory to complement the left internal thoracic artery.Results: Angiography was performed in 99 patients (92%) at a mean of 36 months postoperatively. Graft and grafted coronary artery patency was evaluated. The patency of grafts for no-touch saphenous vein and radial artery was 94% versus 82% (p = 0.01), respectively. The patency of coronary arteries grafted with no-touch saphenous vein and radial artery grafts was 95% versus 84% (p = 0.005), respectively. Eighty-nine of 96 (93%) left internal thoracic artery grafts were patent.Conclusions: No-touch saphenous vein grafts showed a significantly higher patency rate than the radial artery grafts and the patency was comparable to the patency for left internal thoracic artery grafts. This highlights the improvement in saphenous vein graft quality with the no-touch technique and increases the number of situations in which saphenous veins may be preferable to radial artery grafts as conduits in coronary artery bypass grafting.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

Medicine
Medicin

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy