SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:oru-41166"
 

Sökning: id:"swepub:oai:DiVA.org:oru-41166" > Comparison of MP AE...

Comparison of MP AES and ICP-MS for analysis of principal and selected trace elements in nitric acid digests of sunflower (Helianthus annuus)

Karlsson, Stefan, 1957- (författare)
Örebro universitet,Institutionen för naturvetenskap och teknik,Man-Technology-Environment Research Centre
Sjöberg, Viktor, 1984- (författare)
Örebro universitet,Institutionen för naturvetenskap och teknik,Man-Technology-Environment Research Centre
Ogar, Anna, 1985- (författare)
Plant-Microbial Interactions, Institute of Environmental Sciences, Jagiellonian University, Kraków, Poland
 (creator_code:org_t)
Elsevier BV, 2015
2015
Engelska.
Ingår i: Talanta. - : Elsevier BV. - 0039-9140 .- 1873-3573. ; 135, s. 124-132
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The use of nitrogen as plasma gas for microwave plasma atomic emission spectroscopy (MP AES) is an interesting development in analytical science since the running cost can be significantly reduced in comparison to the inductively coupled argon plasma. Here, we evaluate the performance of the Agilent 4100 MP AES instrument for the analysis of principal metals (Ca, K, Mg, and Na), lithogenic metals (Al, Fe, and Mn) and selected trace metals (As, Ba, Cd, Co, Cr, Cu, Mo, Ni, Pb, V, and Zn) in nitric acid plant digests. The digests were prepared by microwave-assisted dissolution of dry plant material from sunflower (Helianthus annuus) in concentrated nitric acid. Comparisons are made with analysis of the same solutions with ICP-MS (Agilent 7500cx) using the octopole reaction system (ORS) in the collision mode for As, Fe, and V.The limits of detection were usually in the low μg L-1 range and all principal and lithogenic metals were successfully determined with the MP AES and provided almost identical results with the ICP-MS. The same applies for the selected trace metals except for As, Co and Mo where the concentrations were below the detection limit with the MP AES. For successful analysis we recommend that (i) only atom lines are used, (ii) ionization is minimized (e.g. addition of CsNO3) and (iii) the use of internal standards should be considered to resolve spectral interferences.

Ämnesord

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Nyckelord

Digestion; ICP-MS; Macro and trace elements; MP AES
Chemistry
Kemi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Talanta (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Karlsson, Stefan ...
Sjöberg, Viktor, ...
Ogar, Anna, 1985 ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
Artiklar i publikationen
Talanta
Av lärosätet
Örebro universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy