SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:oru-50375"
 

Sökning: id:"swepub:oai:DiVA.org:oru-50375" > Correction for disp...

Correction for displacement artifacts in 3D phase contrast imaging

Thunberg, Per, 1968- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Klinisk fysiologi,Hälsouniversitetet
Wigström, Lars, 1967- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Klinisk fysiologi,Hälsouniversitetet
Ebbers, Tino, 1972- (författare)
Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet
visa fler...
Karlsson, Matts, 1965- (författare)
Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan
visa färre...
 (creator_code:org_t)
2002-10-28
2002
Engelska.
Ingår i: Journal of Magnetic Resonance Imaging. - Hoboken, USA : John Wiley & Sons. - 1053-1807 .- 1522-2586. ; 16:5, s. 591-597
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To correct for displacement artifacts in 3D phase contrast imaging.Materials and Methods: A 3D phase contrast pulse sequence was modified so that displacements of velocity measurements were restricted to one direction. By applying a postprocessing method, displaced measurements could be traced back to their accurate positions. Flow studies were performed using a phantom that generated flow through a stenosis, directed oblique relative to the phase and frequency encoding directions. Velocity profiles and streamline visualization were used to compare displaced and corrected velocity data to a reference.Results: Velocity profiles obtained from the original measurement showed skewed profiles due to the displacement artifact, both at close proximity to the orifice as well as further downstream. After correction, concordance with the reference improved considerably.Conclusion: The displacement artifact, which restricts the accuracy of phase contrast measurements, can be corrected for using the proposed method. Correction of the phase contrast velocity data may improve the accuracy of subsequent flow analysis and visualization.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Convective acceleration
expansion point
stenosis
phase contrast
displacement artifacts
MEDICINE

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy