SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:oru-71655"
 

Sökning: id:"swepub:oai:DiVA.org:oru-71655" > Translating Glycate...

Translating Glycated Hemoglobin A1c into Time Spent in Glucose Target Range : a Multicenter Study

Petersson, Jonathan (författare)
School of Medical Sciences, Örebro University, Örebro, Sweden,Orebro Univ, Sweden
Åkesson, Karin (författare)
Linköpings universitet,Avdelningen för barns och kvinnors hälsa,Medicinska fakulteten,Ryhov Cty Hosp, Sweden
Sundberg, Frida (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för pediatrik,Institute of Clinical Sciences, Department of Pediatrics
visa fler...
Särnblad, Stefan, 1963- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,Department of Pediatrics, University Hospital Örebro, Örebro, Sweden,Orebro Univ, Sweden; Univ Hosp Orebro, Sweden
visa färre...
 (creator_code:org_t)
2019-01-31
2019
Engelska.
Ingår i: Pediatric Diabetes. - : Blackwell Publishing. - 1399-543X .- 1399-5448. ; 20:3, s. 339-344
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Approximately 90% of children and adolescents with type 1 diabetes in Sweden use continuous glucose monitoring (CGM), either as real-time CGM or intermittently scanned CGM to monitor their glucose levels. Time in target range (TIT) is an easily understandable metric for assessing glycemic control.Objective: The aim of this study was to examine the relation between TIT and hemoglobin A1c (HbA1c).Subjects and Methods: Subjects were recruited from three diabetes care centers in Sweden. Glucose data were collected for 133 children and adolescents with type 1 diabetes through CGM using Diasend. Subjects with registration time over 80% were included in the analysis. HbA1c was collected from SWEDIABKIDS, the Swedish pediatric diabetes quality registry. TIT was defined as 3.9 to 7.8 mmol/L (70-140 mg/dL) and time in range (TIR) as 3.9 to 10 mmol/L (70-180 mg/dL).Results: During the period of 60 days, 105 subjects provided complete data for analysis. Mean age was 12.2 (±3.3) years, mean HbA1c was 53.9 (±8.2) mmol/mol or 7.1% (±0.7%). Mean sensor glucose value was 8.6 (±1.3) mmol/L, mean coefficient of variation was 42.2% (±7.2%), mean TIT was 40.9% (±SD 12.2%), and mean TIR was 60.8% (±13.1%). There was a significant nonlinear relation between TIT during 60 days and HbA1c, R 2 = 0.69.Conclusion: This study suggests a nonlinear relation between time spent in glucose target range and HbA1c. The finding implies that time spent in TIT could be a useful metric in addition to HbA1c to assess glycemic control.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Pediatrik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Pediatrics (hsv//eng)

Nyckelord

HbA1c
Type 1 diabetes
children
continuous glucose monitoring
time in target range

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy