SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:oru-81840"
 

Sökning: id:"swepub:oai:DiVA.org:oru-81840" > Second trimester ce...

Second trimester cervical length measurements with transvaginal ultrasound : a prospective observational agreement and reliability study

Kuusela, Pihla (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för obstetrik och gynekologi,Institute of Clinical Sciences, Department of Obstetrics and Gynecology
Wennerholm, Ulla-Britt, 1948 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för obstetrik och gynekologi,Institute of Clinical Sciences, Department of Obstetrics and Gynecology
Fadl, Helena, 1965- (författare)
Örebro University,Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Departement of Obstetrics and Gynecology,Örebro Univ, Fac Med & Hlth, Dept Obstet & Gynecol, Örebro, Sweden.
visa fler...
Wesström, Jan, 1963- (författare)
Uppsala University,Uppsala universitet,Centrum för klinisk forskning Dalarna,Institutionen för kvinnors och barns hälsa,Falun Central Hospital
Lindgren, Peter (författare)
Karolinska Institutet
Hagberg, Henrik, 1955 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för obstetrik och gynekologi,Institute of Clinical Sciences, Department of Obstetrics and Gynecology
Jacobsson, Bo, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för obstetrik och gynekologi,Institute of Clinical Sciences, Department of Obstetrics and Gynecology
Valentin, Lil (författare)
Lund University,Lunds universitet,Obstetrisk, gynekologisk och prenatal ultraljudsdiagnostik,Forskargrupper vid Lunds universitet,Obstetric, Gynaecological and Prenatal Ultrasound Research,Lund University Research Groups,Skåne University Hospital
visa färre...
 (creator_code:org_t)
2020-05-21
2020
Engelska.
Ingår i: Acta Obstetricia et Gynecologica Scandinavica. - : John Wiley & Sons. - 0001-6349 .- 1600-0412. ; 99:11, s. 1476-1485
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • INTRODUCTION: Universal screening for preterm delivery by adding transvaginal ultrasound measurement of cervical length to routine second trimester ultrasound has been proposed. The aim is to estimate inter- and intra-observer agreement and reliability of second trimester transvaginal ultrasound measurements of cervical length performed by specially trained midwife sonographers.MATERIAL AND METHODS: This is a prospective reliability and agreement study performed in seven Swedish ultrasound centers. In total, 18 midwife sonographers specially trained to perform ultrasound measurements of cervical length and 286 women in the second trimester were included. In each center two midwife sonographers measured cervical length a few minutes apart in the same woman, the number of women examined per examiner pair varying between 24 and 30 (LIVE study). Sixteen midwife sonographers measured cervical length twice ≥2 months apart on 93 video-clips (CLIPS study). The main outcome measures were mean difference, limits of agreement, intra-class correlation coefficient, intra-individual standard deviation, repeatability, Cohen´s kappa, and Fleiss kappa.RESULTS: The limits of agreement and intra-class correlation coefficient of the best examiner pair in the LIVE study were -4.06 to 4.72 mm and 0.91, those of the poorest were -11.11 to 11.39 mm and 0.31. In the CLIPS study, median (range) intra-individual standard deviation was 2.14 mm (1.40 to 3.46), repeatability 5.93 mm (3.88 to 9.58), intra-class correlation coefficient 0.84 (0.66 to 0.94). Median (range) inter-observer agreement for cervical length ≤25 mm in the CLIPS study was 94.6% (84.9% to 98.9%) and Cohen´s kappa 0.56 (0.12 to 0.92), median (range) intra-observer agreement was 95.2% (87.1% to 98.9%) and Cohen´s kappa 0.68 (0.27 to 0.93).CONCLUSIONS: Agreement and reliability of cervical length measurements differed substantially between examiner pairs and examiners. If cervical length measurements are used to guide management there is potential for both over- and under-treatment. Uniform training and rigorous supervision and quality control are advised.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Reproduktionsmedicin och gynekologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Obstetrics, Gynaecology and Reproductive Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Reproducibility of results
cervical length
cervical length measurement
data accuracy
inter-observer variation
intra-observer variation
preterm delivery
quality control
second trimester of pregnancy
transvaginal ultrasound
cervical length
cervical length measurement
data accuracy
inter-observer variation
intraobserver variation
preterm delivery
quality control
reproducibility of results
second trimester of pregnancy
transvaginal ultrasound

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy