SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:oru-83727"
 

Search: id:"swepub:oai:DiVA.org:oru-83727" > Test-retest and int...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Test-retest and inter-rater reliability of a method to measure wrist and finger spasticity

Gäverth, Johan (author)
Karolinska Institutet
Sandgren, Maria (author)
Karolinska Institute, Stockholm, Sweden
Lindberg, Påvel G (author)
Karolinska Institutet
show more...
Forssberg, Hans (author)
Karolinska Institutet
Eliasson, Ann-Christin, 1950- (author)
Karolinska Institutet
show less...
 (creator_code:org_t)
Foundation for Rehabilitation Information, 2013
2013
English.
In: Journal of Rehabilitation Medicine. - : Foundation for Rehabilitation Information. - 1650-1977 .- 1651-2081. ; 45:7, s. 630-636
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • OBJECTIVE: To describe the reliability of an instrument (Neuro- Flexor) designed to be used in the clinic for quantification of the relative contribution of spasticity, elasticity and viscosity to resistance during passive wrist movements.DESIGN: A test-retest and inter-rater reliability study.SUBJECTS: A convenience sample of 34 adults with chronic stroke with spasticity in the hand, and a reference group of 10 healthy persons.METHODS: Two raters assessed the participants with the NeuroFlexor. Elastic, viscous and neural components of passive movement resistance were quantified at the wrist. Test-retest and inter-rater intraclass correlation coefficient (ICC2.1) were calculated for each component for both raters and two sessions. Degree of measurement error was evaluated using the coefficient of variation and the repeatability coefficient.RESULTS: Reliability was high for the neural component (test-retest: 0.90-0.96; inter-rater: 0.90-0.94), fair to good for the elastic component (test-retest: 0.79-0.88; inter-rater: 0.76-0.76), and fair to high for the viscous component (test-retest: 0.88-0.90; inter-rater: 0.75-0.80). Based on test-retest data, the coefficients of variation for the neural, elastic and viscous components were 25%, 26% and 16%, respectively, and the repeatability coefficients were 1.798, 1.897 and 1.404, respectively.CONCLUSION: The NeuroFlexor instrument is a reliable measure of spasticity and of muscle elasticity and viscosity in individuals with wrist and finger muscle resistance to passive stretch after stroke.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Pediatrik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Pediatrics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsterapi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Therapy (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)

Keyword

Hand
medical instrument
outcome assessment
muscle spasticity
stroke
upper extremity
wrist

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Gäverth, Johan
Sandgren, Maria
Lindberg, Påvel ...
Forssberg, Hans
Eliasson, Ann-Ch ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Pediatrics
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Health Sciences
and Occupational The ...
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Neurology
Articles in the publication
Journal of Rehab ...
By the university
Örebro University
Karolinska Institutet

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view