Real-world performance of the MiniMed™ 670G system in Europe

Da Silva, Julien (författare)
Medtronic International Trading Sàrl, Tolochenaz, Switzerland
Bosi, Emanuele (författare)
Diabetes Research Institute, IRCCS San Raffaele Hospital and San Raffaele Vita Salute University, Milan, Italy
Jendle, Johan, 1963- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,Department of Medical Sciences
visa fler...
Arrieta, Arcelia (författare)
Medtronic Bakken Research Center, Maastricht, Netherlands
Castaneda, Javier (författare)
Medtronic Bakken Research Center, Maastricht, Netherlands
Grossman, Benyamin (författare)
Medtronic, Northridge, California, USA
Cordero, Toni L. (författare)
Medtronic, Northridge, California, USA
Shin, John (författare)
Medtronic, Northridge, California, USA
Cohen, Ohad (författare)
Medtronic International Trading Sàrl, Tolochenaz, Switzerland
visa färre...
 (creator_code:org_t)
2021-05-27
2021
Engelska.
Ingår i: Diabetes, obesity and metabolism. - : Wiley-Blackwell Publishing Inc.. - 1462-8902 .- 1463-1326. ; 23:8, s. 1942-1949
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • AIMS: The MiniMed™ 670G system has been available in Europe since October 2018. Herein, the system's real-world performance in individuals with diabetes is evaluated.MATERIALS AND METHODS: Data uploaded October 2018 to July 2020 by individuals living in Europe were aggregated and retrospectively analyzed. The mean Glucose Management Indicator (GMI), percentage of time spent within (TIR), below (TBR) and above (TAR) glycemic ranges, system use and insulin consumed in users with ≥10 days of SG data after initial Auto Mode start were determined. Another analysis based on suboptimally- (GMI >8.0%) and well-controlled (GMI <7.0%) glycemia pre-Auto Mode initiation was also performed.RESULTS: Users (N=14,899) spent a mean of 81.4% of the time in Auto Mode and achieved a mean GMI of 7.0±0.4%, TIR of 72.0±9.7%, TBR <3.9 mmol/L of 2.4±2.1% and TAR >10 mmol/L of 25.7±10%, after initiating Auto Mode. When compared to pre-Auto Mode initiation, GMI reduced by 0.3±0.4% and TIR increased by 9.6±9.9% (p<0.0001 for both). Significantly improved glycemic control was observed irrespectively of pre-Auto Mode GMI level <7.0% or >8.0%. While total daily dose of insulin increased for both groups, a greater increase was observed in the latter: an increase due primarily to increased basal insulin delivery. In contrast, basal insulin decreased slightly in well-controlled users.CONCLUSIONS: Most MiniMed™ 670G system users in Europe achieved TIR >70% and GMI <7% while minimizing hypoglycemia, in a real-world environment. These international consensus-met outcomes were enabled by automated insulin delivery meeting real-time insulin requirements adapted to each individual user.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Endokrinologi och diabetes (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Endocrinology and Diabetes (hsv//eng)

Nyckelord

closed-loop system
diabetes
glucose management indicator
hyperglycaemia
hypoglycaemia
real-world evidence
time in range

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy