Sökning: id:"swepub:oai:DiVA.org:ri-29603" >
Spilled liquid fire...
Abstract
Ämnesord
Stäng
- The study focuses on release of liquids inside tunnels from tankers containing dangerous good. Experiments and analysis from large scale tests are presented. The tests include different leakage rates, leakage type, liquids, spillage sizes on sloping surfaces and heat release rates. Models for estimation of leakage rates, spillage sizes and heat release rates for different scenarios are presented. The results are important to use in the design of active fire protections systems in tunnels including ventilation, fixed fire-fighting and drainage systems.
Nyckelord
- Dangerous goods
- Fire
- Heat release rate
- Leakage rate
- Spillage
- Spilled liquid
- Tunnels
- Fire extinguishers
- Fire fighting equipment
- Fires
- Drainage systems
- Fire fighting
- Heat Release Rate (HRR)
- Large scale tests
- Leakage rates
- Sloping surfaces
- Liquids
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas