Sökning: id:"swepub:oai:DiVA.org:ri-37541" >
Extinguishing smold...
Extinguishing smoldering fires in wood pellets through cooling
-
- Fjellgaard Mikalsen, Ragni (författare)
- RISE,Fire Research Norge,Western Norway University of Applied Sciences, Norway
-
- Hagen, Bjarne Christian (författare)
- Western Norway University of Applied Sciences, Norway
-
- Steen-Hansen, Anne (författare)
- RISE,Fire Research Norge
-
visa fler...
-
- Frette, Vidar (författare)
- Western Norway University of Applied Sciences, Norway
-
visa färre...
-
(creator_code:org_t)
- 2017
- 2017
- Engelska.
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.9...
-
visa färre...
Abstract
Ämnesord
Stäng
- Extinguishing smoldering fires is a severe challenge for fire brigades, and has proven to be difficult even on the lab scale. In this study, the influence of a closed water cooling loop located within the fuel bed was investigated experimentally. Increasing the cooling led to a system less prone to intense combustion at an early stage, and eventually to complete extinguishment of self-sustained smoldering fires. Extinguishment was obtained in half of the cases with maximum cooling. Extinguishment occurred soon after smoldering had been established, giving a significant reduction in fuel consumption compared to the self-sustained smoldering fires that continued to complete burn-out.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Annan teknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Other Engineering and Technologies (hsv//eng)
Publikations- och innehållstyp
- vet (ämneskategori)
- kon (ämneskategori)