Biomechanical and histomorphometric evaluation of skin integration on titanium and PEEK implants with different surface treatments

Kjellin, Per (författare)
Promimic AB, Sweden
Danielsson, Karin (författare)
Promimic AB, Sweden
Håkansson, Joakim (författare)
Gothenburg University,Göteborgs universitet,RISE,Metodik för produktframtagning,University of Gothenburg, Sweden,Institutionen för biomedicin, avdelningen för laboratoriemedicin,Department of Laboratory Medicine
visa fler...
Agrenius, Karin (författare)
RISE,Kemi och Tillämpad mekanik
Andersson, Therese (författare)
RISE,Metodik för produktframtagning
Stenlund, Patrik (författare)
RISE,Metodik för produktframtagning
visa färre...
 (creator_code:org_t)
2022-09-30
2022
Engelska.
Ingår i: Journal of materials science. Materials in medicine. - : Springer. - 0957-4530 .- 1573-4838. ; 33:10
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Percutaneous implants are frequently affected by bacterial growth at the skin-implant interface. Integration between implant and surrounding skin is important to prevent bacteria from spreading to the underlying tissue. The standard method to evaluate skin-implant integration is by histomorphometry on samples which have been placed in tissue grown in vivo or ex vivo. In this study, a biomechanical method was developed and evaluated. The integration of implants into porcine skin was studied in an ex vivo model, where pig skin samples were cultivated in a nutrient solution. Cylindrical shaped implants, consisting of polyether ether ketone (PEEK) and titanium (Ti) with different surface treatments, were implanted in the skin tissue and the skin was grown in nutrient solution for 2 weeks. The implants were then extracted from the implantation site and the mechanical force during extraction was measured as a quantitative assessment of skin-implant integration. Implants from each group were also processed for histomorphometry and the degree of epidermal downgrowth (ED) and tissue to implant contact (TIC) was measured. A higher mean pullout force was observed for the PEEK implants compared to the Ti implants. Applying nanosized hydroxyapatite (HA) on Ti and PEEK increased the pullout force compared to uncoated controls, 24% for machined and 70% for blasted Ti, and 51% for machined PEEK. Treatment of Ti and PEEK with nanosized zirconium phosphate (ZrP) did not increase the pullout force. The histomorphometry analysis showed correlation between ED and pullout force, where the pullout force was inversely proportional to ED. For TIC, no significant differences were observed between the groups of same material (i.e. Ti, Ti+HA, Ti+ZrP, and PEEK, PEEK + HA, PEEK + ZrP), but it was significantly higher for PEEK compared to Ti. Scanning electron microscopy analysis was done on samples before and after the pullout tests, showing that the ZrP coating was unaffected by the 2 week ex vivo implantation and pullout procedure, no dissolution or detachment of the coating was observed. For the HA coating, a loss of coating was seen on approximately 5% of the total surface area of the implant. [Figure not available: see fulltext.] © 2022, The Author(s).

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Annan medicinsk bioteknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Other Medical Biotechnology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Bacteria
Biocompatibility
Biomechanics
Coatings
Ethers
Integration
Ketones
Mammals
Nutrients
Scanning electron microscopy
Tissue
Titanium carbide
Bacterial growth
Ex-vivo
Histomorphometry
Implant interfaces
In-vivo
Nutrient solution
Pullout force
Skin implants
Titania
Zirconium phosphate
Hydroxyapatite
nanohydroxyapatite
nanomaterial
polyetheretherketone
titanium
unclassified drug
benzophenone derivative
ether derivative
ketone
macrogol
polymer
animal experiment
animal tissue
Article
bone tissue
coating (procedure)
controlled study
dissolution
ex vivo study
force
implantation
morphometry
nonhuman
quantitative analysis
surface area
surface property
Yorkshire pig
animal
osseointegration
pig
tooth implant
Animals
Benzophenones
Dental Implants
Durapatite
Polyethylene Glycols
Polymers
Surface Properties
Swine
Bacteria
Biocompatibility
Biomechanics
Coatings
Ethers
Integration
Ketones
Mammals
Nutrients
Scanning electron microscopy
Tissue
Titanium carbide
Bacterial growth
Ex-vivo
Histomorphometry
Implant interfaces
In-vivo
Nutrient solution
Pullout force
Skin implants
Titania
Zirconium phosphate
Hydroxyapatite
nanohydroxyapatite
nanomaterial
polyetheretherketone
titanium
unclassified drug
benzophenone derivative
ether derivative
ketone
macrogol
polymer
animal experiment
animal tissue
Article
bone tissue
coating (procedure)
controlled study
dissolution
ex vivo study
force
implantation
morphometry
nonhuman
quantitative analysis
surface area
surface property
Yorkshire pig
animal
osseointegration
pig
tooth implant
Animals
Benzophenones
Dental Implants
Durapatite
Polyethylene Glycols
Polymers
Surface Properties
Swine

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy