SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:ri-70085"
 

Sökning: id:"swepub:oai:DiVA.org:ri-70085" > 106.25 Gbaud On-Off...

106.25 Gbaud On-Off Keying and Pulse Amplitude Modulation Links Supporting Next Generation Ethernet on Single Lambda

Ostrovskis, A. (författare)
Riga Technical University, Latvia
Salgals, T. (författare)
Riga Technical University, Latvia
Krüger, B. (författare)
Keysight Technologies GmbH, Germany
visa fler...
Pittalà, F. (författare)
Keysight Technologies GmbH, Germany
Joharifar, M. (författare)
KTH Royal Institute of Technology, Sweden
Schatz, Richard (författare)
KTH Royal Institute of Technology, Sweden
Koenigsmann, M. (författare)
Keysight Technologies GmbH, Germany
Fan, Yuchuan (författare)
RISE,Industriella system
Chacinski, M. (författare)
Coherent, Sweden
Westergren, U. (författare)
KTH Royal Institute of Technology, Sweden
Zhang, L. (författare)
Zhejiang University, China; Zhejiang Lab, China
Mardoyan, H. (författare)
Nokia Bell Labs, France
Spolitis, S. (författare)
Riga Technical University, Latvia
Popov, S. (författare)
KTH Royal Institute of Technology, Sweden
Yu, X. (författare)
Zhejiang University, China; Zhejiang Lab, China
Gruen, M. (författare)
Keysight Technologies GmbH, Germany
Bobrovs, V. (författare)
Riga Technical University, Latvia;
Louchet, H. (författare)
Keysight Technologies GmbH, Germany
Pang, Xiaodan, Dr. (författare)
RISE,Industriella system,Riga Technical University, Latvia; KTH Royal Institute of Technology, Sweden
Ozolins, Oskars (författare)
RISE,Industriella system
visa färre...
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: Journal of Lightwave Technology. - 0733-8724 .- 1558-2213. ; 42:4, s. 1272-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Development of Data Center based computing technology require energy efficient high-speed transmission links. This leads to optical amplification-free intensity modulation and direct detection (IM/DD) systems with low complexity equalization compliant with IEEE standardized electrical interfaces. Switching from on-off keying to multi-level pulse amplitude modulation would allow to reduce lane count for next generation Ethernet interfaces. We characterize 106.25 Gbaud on-off keying, 4-level and 6-level pulse amplitude modulation links using two integrated transmitters: O-band directly modulated laser and C-band externally modulated laser. Simple feed forward or decision feedback equalizer is used. We demonstrate 106.25 Gbaud on-off keying links operating without forward error correction for both transmitters. We also show 106.25 Gbaud 4-level and 6-level pulse amplitude modulation links with performance below 6.25% overhead hard-decision forward error threshold of 4.5×10-3. Furthermore, for EML-based transmitter we achieve 106.25 Gbaud 4-level pulse amplitude modulation performance below KP-FEC threshold of 2.2×10-4. That shows that we can use optics to support (2x)100 Gbps Ethernet on single lambda at expense of simple forward error correction.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy