SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:ri-71939"
 

Sökning: id:"swepub:oai:DiVA.org:ri-71939" > Procedure for autom...

Procedure for automated low uncertainty assessment of empty cavity mode frequencies in Fabry-Pérot cavity based refractometry

Zakrisson, Johan (författare)
Umeå universitet,Institutionen för fysik,Measurement Science and Technology, RISE Research Institutes of Sweden, Borås, Sweden,Umeå University, Sweden
Silander, Isak, 1980- (författare)
Umeå universitet,Institutionen för fysik,Umeå University, Sweden
Silva de Oliveira, Vinicius (författare)
Umeå universitet,Institutionen för fysik,Umeå University, Sweden
visa fler...
Hjältén, Adrian, 1988- (författare)
Umeå universitet,Institutionen för fysik,Umeå University, Sweden
Rosina, Andrea (författare)
Umeå universitet,Institutionen för fysik,Umeå University, Sweden
Rubin, Tom (författare)
Physikalisch-Technische Bundesanstalt (PTB), Abbestr 2-12, Berlin, Germany
Foltynowicz, Aleksandra, 1981- (författare)
Umeå universitet,Institutionen för fysik,Umeå University, Sweden
Zelan, Martin (författare)
RISE,Mätteknik,Measurement Science and Technology, RISE Research Institutes of Sweden, Borås, Sweden
Axner, Ove (författare)
Umeå universitet,Institutionen för fysik,Umeå University, Sweden
visa färre...
 (creator_code:org_t)
Optica Publishing Group (formerly OSA), 2024
2024
Engelska.
Ingår i: Optics Express. - : Optica Publishing Group (formerly OSA). - 1094-4087. ; 32:3, s. 3959-3973
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A procedure for automated low uncertainty assessment of empty cavity mode frequencies in Fabry-Pérot cavity based refractometry that does not require access to laser frequency measuring instrumentation is presented. It requires a previously well-characterized system regarding mirror phase shifts, Gouy phase, and mode number, and is based on the fact that the assessed refractivity should not change when mode jumps take place. It is demonstrated that the procedure is capable of assessing mode frequencies with an uncertainty of 30 MHz, which, when assessing pressure of nitrogen, corresponds to an uncertainty of 0.3 mPa. 

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)
NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Nyckelord

Cavity resonators
Fabry-Perot interferometers
Fiber optic sensors
nitrogen
Cavity-mode frequencies
Fabry-Perot cavity
Gouy phase
Laser frequency
Mode frequencies
Mode number
Phase number
Refractometry
Uncertainty
Uncertainty assessment
adolescent
adult
article
female
frequency
human
laser
male
normal human
pressure
surgery
therapy
Uncertainty analysis

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy