Measurement uncertainty as a tool for evaluating the ‘grey zone’ to reduce the false negatives in immunochemical screening of blood donors for infectious diseases

Pereira, Paulo (författare)
Portuguese Institute of Blood and Transplantation, Portugal,Portuguese Institute Blood and Transplantat, Portugal
Magnusson, Bertil (författare)
RISE,Kemi,SP Technical Research Institute Sweden, Sweden
Theodorsson, Elvar (författare)
Linköpings universitet,Avdelningen för mikrobiologi och molekylär medicin,Medicinska fakulteten,Region Östergötland, Klinisk kemi
visa fler...
Westgard, James O. (författare)
University of Wisconsin, WI USA
Encarnação, Pedro (författare)
Catholic University of Portugal, Portugal
visa färre...
 (creator_code:org_t)
2015-11-24
2016
Engelska.
Ingår i: Accreditation and Quality Assurance. - : Springer-Verlag New York. - 0949-1775 .- 1432-0517. ; 21:1, s. 25-32
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The risk of misclassifying infected individuals as healthy constitutes a crucial challenge when screening blood donors by means of immunoassays. This risk is especially challenging when the numerical results are close to the clinical decision level, i.e. in the ‘grey zone’. The concept of using measurement uncertainty for evaluating the ‘grey zone’ has previously not been systematically applied in this context. This article explains methods, models and empirical (top-down) approaches for the calculation of measurement uncertainty using results from a blood bank according to the internationally accepted GUM principles, focusing on uncertainty sources in the analytical phase. Of the different approaches available, the intralaboratory empirical approaches are emphasised since modelling (bottom-up) approaches are impracticable due to the lack of reliable model equations for immunoassays. Different methods are applied to estimate the measurement uncertainty for the Abbott Prism® HCV immunoassay. The expanded uncertainty obtained at the clinical decision level from the intralaboratory empirical approach was 36 %. The estimated uncertainty was used to set acceptance and rejection zones following the procedure set in the Eurachem guideline, emphasising the need to minimise the occurrence of false negatives.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
NATURVETENSKAP  -- Matematik -- Sannolikhetsteori och statistik (hsv//swe)
NATURAL SCIENCES  -- Mathematics -- Probability Theory and Statistics (hsv//eng)
NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Nyckelord

blood bank
clinical decision level
cut-off value
GUM
immunoassay
measurement uncertainty
screening test
‘grey zone’

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy