SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:rkh-2496"
 

Sökning: id:"swepub:oai:DiVA.org:rkh-2496" > Evaluation of centr...

Evaluation of central venous catheters coated with a noble metal alloy - A randomized clinical pilot study of coating durability, performance and tolerability

Björling, Gunilla (författare)
Röda Korsets Högskola,Hälsovetenskapliga institutionen,Karolinska Institutet
Johansson, Dorota (författare)
Bactiguard, Stockholm
Bergström, Linda (författare)
Bactiguard, Stockholm
visa fler...
Strekalovsky, Anton (författare)
Karolinska University Hospital
Sanchez, Javier (författare)
Karolinska Institutet / Bactiguard, Stockholm
Frostell, Claes (författare)
Karolinska Institutet
Kalman, Sigridur (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2017-11-06
2018
Engelska.
Ingår i: Journal of Biomedical Materials Research. Part B - Applied biomaterials. - : John Wiley & Sons. - 1552-4973 .- 1552-4981. ; 106:6, s. 2337-2344
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The use of Central Venous Catheters (CVCs) commonly results in complications. Coatings with silver or metal alloys can reduce the risk associated with the use of CVC. We have evaluated the durability of a noble metal coated CVC (the Bactiguard Infectious Protection, BIP CVC) and compared with an uncoated CVC for clinical tolerability (Adverse Events, AEs) and performance, in order to create a baseline for a large future study. Patients undergoing major surgery, randomised at a 2:1 ratio to BIP CVC (n = 22) or standard CVC (n = 12), were catheterized 9 - 12 days, respectively. Adverse events, microbial colonization and metal release were measured.FINDINGS: There were no AEs in the BIP CVC-group, but 5 AEs occurred in 4 patients (1 patient had 2 AEs) in the standard CVC-group, p = 0.011 (whereof 3 were catheter related). The BIP CVC showed an initial release of coating metals in blood (gold, silver and palladium), which rapidly decreased and were far below Permitted Paily Exposure (PDE) for chronical use. The levels of silver concentration were far below those needed to develop microbial resistance. The performance was equal, and there was no difference concerning microbial colonization, for the two CVCs.CONCLUSION: In this pilot study the BIP CVC had significantly lower AEs and showed a comparable performance to the standard CVC. The coating was durable throughout the study length (up to 16 days) and toxicological evaluation showed good safety margins. Larger studies are needed.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Omvårdnad (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Nursing (hsv//eng)

Nyckelord

central venous catheter
colonization
noble metal alloy coating
performance
tolerability

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy