SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:sh-47754"
 

Sökning: id:"swepub:oai:DiVA.org:sh-47754" > Single-site samplin...

Single-site sampling versus multi-site sampling for blood cultures; A retrospective clinical study

Larsson, Anna (författare)
Karolinska Institutet, Sweden
Yu, David (författare)
Karolinska Institutet
Dinnétz, Patrik (författare)
Södertörns högskola,Miljövetenskap
visa fler...
Nordqvist, Hampus (författare)
Stockholm South Hospital, Sweden
Özenci, Volkan (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
American Society for Microbiology, 2022
2022
Engelska.
Ingår i: Journal of Clinical Microbiology. - : American Society for Microbiology. - 0095-1137 .- 1098-660X. ; 60:2
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives The performance of blood cultures (BC) relies on optimal sampling. Sepsis guidelines do not specify which sampling protocol to use, but recommend two sets of BC bottles, each set containing one aerobic and one anaerobic bottle. For the single-site sampling (SSS) protocol, only one venipuncture is performed for all four bottles. The predominating multi-site sampling (MSS) protocol implies that BC bottles are collected from two separate venipuncture sites. The aim of this study was to compare SSS and MSS. Primary outcomes were number of BC sets collected, sample volume and diagnostic performance. Methods This was a retrospective clinical study comparing BC results in an emergency department before and after changing the sampling protocol to SSS from MSS. All BC samples were incubated in the BacT/ALERT BC system. Results The analysis included 5,248 patients before and 5,364 patients after the implementation of SSS. There was a significantly higher proportion of positive BCs sampled with SSS compared to MSS, 1,049/5,364 (19.56%) and 932/5,248 (17.76%) respectively (P=0.018). This difference was due to a higher proportion of solitary BC sets (two BC bottles) in MSS. Analyzing only patients with the recommended four BC bottles, there was no difference in positivity. SSS had a higher proportion of BC bottles with the recommended sample volumes of 8-12 ml than MSS (P<0.001). Conclusions Changing the sampling protocol to SSS from MSS resulted in higher positivity rates, higher sample volume and fewer solitary BC sets. These advantages of SSS should be considered in future sepsis guidelines.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy