SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:su-104596"
 

Sökning: id:"swepub:oai:DiVA.org:su-104596" > Sensitivity of salm...

Sensitivity of salmonella YG5161 for detecting PAH-associated mutagenicity in air particulate matter

Umbuzeiro, Gisela A. (författare)
Kummrow, Fábio (författare)
Morales, Daniel Alexandre (författare)
visa fler...
Alves, Debora Kristina M. (författare)
Lim, Hwanmi (författare)
Stockholms universitet,Institutionen för analytisk kemi
Jarvis, Ian W. H. (författare)
Bergvall, Christoffer (författare)
Stockholms universitet,Institutionen för analytisk kemi
Westerholm, Roger (författare)
Stockholms universitet,Institutionen för analytisk kemi
Stenius, Ulla (författare)
Karolinska Institutet
Dreij, Kristian (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
 
visa fler...
 
visa färre...
ISSN 0893-6692
2014-02-28
2014
Engelska.
Ingår i: Environmental and Molecular Mutagenesis. - Stockholm : Wiley. - 0893-6692 .- 1098-2280. ; 55:6, s. 510-517
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The Salmonella/microsome assay is the most used assay for the evaluation of air particulate matter (PM) mutagenicity and a positive correlation between strain TA98 responses and benzo[a]pyrene (B[a]P) levels in PM has been found. However, it seems that the major causes of PM mutagenicity in this assay are the nitro and oxy-PAHs. Salmonella YG5161, a 30-times more responsive strain to B[a]P has been developed. To verify if YG5161 strain was sufficiently sensitive to detect mutagenicity associated with B[a]P mutagenicity, PM samples were collected in Brazil and Sweden, extracted with toluene and tested in the Salmonella/microsome microsuspension assay. PAHs and B[a]P were determined and the extracts were tested with YG5161 and its parental strain TA1538. The extracts were also tested with YG1041 and its parental strain TA98. For sensitivity comparisons, we tested B[a]P and 1-nitropyrene (1-NP) using the same conditions. The minimal effective dose of B[a]P was 155 ng/plate for TA1538 and 7 ng/plate for YG5161. Although the maximum tested dose, 10 m3/plate containing 9 ng of B[a]P in the case of Brazilian sample, was sufficient to elicit a response in YG5161, mutagenicity was detected at a dose as low as 1 m3/plate (0.9 ng). This is probably caused by nitro-compounds that have been shown to be even more potent than B[a]P for YG5161. It seems that the mutagenicity of B[a]P present in PM is not detectable even with the use of YG5161 unless more efficient separation to remove the nitro-compounds from the PAH extract is performed.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

PAHs
salmonella/microsome
nitro-PAHs
mutagenicity
air pollution
Analytical Chemistry
analytisk kemi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy