SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:su-109808"
 

Sökning: id:"swepub:oai:DiVA.org:su-109808" > A needle extraction...

A needle extraction utilizing a molecularly imprinted-sol-gel xerogel for on-line microextraction of the lung cancer biomarker bilirubin from plasma and urine samples

Moein, Mohammad Mahdi (författare)
Stockholms universitet,Institutionen för analytisk kemi
Jabbar, Dunia (författare)
Stockholms universitet,Institutionen för analytisk kemi
Colmsjö, Anders (författare)
Stockholms universitet,Institutionen för analytisk kemi
visa fler...
Abdel-Rehim, Mohamed (författare)
Stockholms universitet,Institutionen för analytisk kemi
visa färre...
 (creator_code:org_t)
Elsevier BV, 2014
2014
Engelska.
Ingår i: Journal of Chromatography A. - : Elsevier BV. - 0021-9673 .- 1873-3778. ; 1366, s. 15-23
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In the present work, a needle trap utilizing a molecularly imprinted sal-gel xerogel was prepared for the on-line microextraction of bilirubin from plasma and urine samples. Each prepared needle could be used for approximately one hundred extractions before it was discarded. Imprinted and non-imprinted sol-gel xerogel were applied for the extraction of bilirubin from plasma and urine samples. The produced molecularly imprinted sol-gel xerogel polymer showed high binding capacity and fast adsorption/desorption kinetics for bilirubin in plasma and urine samples. The adsorption capacity of molecularly imprinted sal-gel xerogel polymer was approximately 60% higher than that of non-imprinted polymer. The effect of the conditioning, washing and elution solvents, pH, extraction time, adsorption capacity and imprinting factor were investigated. The limit of detection and the lower limit of quantification were set to 1.6 and 5 nmol L-1, respectively using plasma or urine samples. The standard calibration curves were obtained within the concentration range of 5-1000 nmol L-1 in both plasma and urine samples. The coefficients of determination values (R-2) were >= 0.998 for all runs. The extraction recovery was approximately 80% for BR in the human plasma and urine samples.

Ämnesord

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)
NATURVETENSKAP  -- Biologi -- Biokemi och molekylärbiologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Biochemistry and Molecular Biology (hsv//eng)

Nyckelord

Molecularly imprinted polymer
Sol-gel
Microextraction by packed sorbent
Bilirubin
Plasma
Urine

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Moein, Mohammad ...
Jabbar, Dunia
Colmsjö, Anders
Abdel-Rehim, Moh ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
NATURVETENSKAP
NATURVETENSKAP
och Biologi
och Biokemi och mole ...
Artiklar i publikationen
Journal of Chrom ...
Av lärosätet
Stockholms universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy