Influence of phantom thickness and material on the backscatter factors for diagnostic x-ray beam dosimetry

Benmakhlouf, Hamza (författare)
Stockholms universitet,Fysikum,Karolinska Institutet, Sweden
Fransson, Annette (författare)
Karolinska Institutet
Andreo, Pedro (författare)
Stockholms universitet,Fysikum,Karolinska Institutet, Sweden
 (creator_code:org_t)
2012-12-21
2013
Engelska.
Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 58:2, s. 247-260
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Most of the existing backscatter factors for the dosimetry of clinical diagnostic x-ray beams have been calculated for 15 cm thick phantoms; these data are used for skin dose determinations which in general ignore the influence of phantom material and thickness. The former should strictly be required whenever dosimetry measurements are made on phantom materials different from those used for the backscatter factor calculations. The phantom or patient thickness is of special importance when skin dose determinations are made for infants or paediatric patients. In this work, the recently published formalism for reference dosimetry and comprehensive database of backscatter factors for clinical beams and water phantoms have been extended using two correction factors which account for phantom material and thickness. These were determined with simulations using the PENELOPE Monte Carlo system, for PMMA to analyse the influence of the phantom material relative to water, and for a broad range of thicknesses of water and PMMA to investigate the role of this parameter in patient dose estimates. The material correction factor was found to be in the range 3-10%, depending on the field size and the HVL. The thickness correction factor was in the range 2-12% for a 5 cm thick phantom and square field sizes between 5 and 35 cm, reaching a plateau of about ±1% for thicknesses beyond 13 cm. Expressions in the form of surface fits over the calculated data are provided which streamline the determination of backscatter factors for arbitrary thicknesses and phantom materials, as well as field sizes. Results demonstrate the inadequacy of using conventional backscatter factors (calculated for 15 cm thick phantoms) without correction factors that take into account the phantom material and its thickness.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Nyckelord

small field dosimetry
Monte Carlo
PENELOPE
output correction factors
medicinsk strålningsfysik
Medical Radiation Physics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Benmakhlouf, Ham ...
Fransson, Annett ...
Andreo, Pedro
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
Artiklar i publikationen
Physics in Medic ...
Av lärosätet
Stockholms universitet
Karolinska Institutet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy