SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:su-161042"
 

Sökning: id:"swepub:oai:DiVA.org:su-161042" > Modelling of a prot...

Modelling of a proton spot scanning system using MCNP6

Ardenfors, Oscar (författare)
Stockholms universitet,Fysikum,Stockholm University, Stockholm, Sweden
Dasu, Alexandru (författare)
Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,The Skandion Clinic, Uppsala, Sweden
Kopeć, Mariusz (författare)
University of Science and Technology, Krakow, Poland
visa fler...
Gudowska, Irena (författare)
Stockholms universitet,Fysikum,Stockholm University, Stockholm, Sweden
visa färre...
 (creator_code:org_t)
2017-06-08
2017
Engelska.
Ingår i: International Nuclear Science and Technology Conference. - : Institute of Physics (IOP). ; 860, s. 012025-
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this work was to model the characteristics of a clinical proton spot scanning beam using Monte Carlo simulations with the code MCNP6. The proton beam was defined using parameters obtained from beam commissioning at the Skandion Clinic, Uppsala, Sweden. Simulations were evaluated against measurements for proton energies between 60 and 226 MeV with regard to range in water, lateral spot sizes in air and absorbed dose depth profiles in water. The model was also used to evaluate the experimental impact of lateral signal losses in an ionization chamber through simulations using different detector radii. Simulated and measured distal ranges agreed within 0.1 mm for R90 and R80 , and within 0.2 mm for R50 . The average absolute difference of all spot sizes was 0.1 mm. The average agreement of absorbed dose integrals and Bragg-peak heights was 0.9%. Lateral signal losses increased with incident proton energy with a maximum signal loss of 7% for 226 MeV protons. The good agreement between simulations and measurements supports the assumptions and parameters employed in the presented Monte Carlo model. The characteristics of the proton spot scanning beam were accurately reproduced and the model will prove useful in future studies on secondary neutrons.

Ämnesord

NATURVETENSKAP  -- Fysik -- Annan fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Other Physics Topics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Nyckelord

Medical Radiation Physics
medicinsk strålningsfysik

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ardenfors, Oscar
Dasu, Alexandru
Kopeć, Mariusz
Gudowska, Irena
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
och Annan fysik
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Cancer och onkol ...
Artiklar i publikationen
Journal of Physi ...
Av lärosätet
Stockholms universitet
Uppsala universitet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy