SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:su-174015"
 

Sökning: id:"swepub:oai:DiVA.org:su-174015" > Spatial correlation...

Spatial correlation of linear energy transfer and relative biological effectiveness with treatment related toxicities following proton therapy for intracranial tumors

Ödén, Jakob (författare)
Stockholms universitet,Fysikum,RaySearch Laboratories AB, Sweden
Toma-Dasu, Iuliana (författare)
Stockholms universitet,Fysikum,Karolinska Institutet, Sweden
Witt Nyström, Petra (författare)
The Skandion Clinic, Sweden
visa fler...
Traneus, Erik (författare)
RaySearch Laboratories AB, Sweden
Dasu, Alexandru (författare)
Uppsala universitet,Institutionen för immunologi, genetik och patologi
visa färre...
 (creator_code:org_t)
2019-12-04
2020
Engelska.
Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405 .- 2473-4209. ; 47:2, s. 342-351
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: The enhanced relative biological effectiveness (RBE) at the end of the proton range might increase the risk of radiation-induced toxicities. This is of special concern for intracranial treatments where several critical organs at risk (OARs) surround the tumor.  In the light of this, a retrospective analysis of dose-averaged linear energy transfer (LETd) and RBE-weighted dose (DRBE) distributions was conducted for three clinical cases with suspected treatment related toxicities following intracranial proton therapy. Alternative treatment strategies aiming to reduce toxicity risks are also presented.Methods: The clinical single-field optimized (SFO) plans were recalculated for 81 error scenarios with a Monte Carlo dose engine. The fractionation DRBE was 1.8 Gy (RBE) in 28 or 30 fractions assuming a constant RBE of 1.1. Two LETd- and α/β-dependent variable RBE models were used for evaluation, including a sensitivity analysis of the α/β parameter. Resulting distributions of DRBE and LETd were analyzed together with normal tissue complication probabilities (NTCPs). Subsequently, four multi-field optimized (MFO) plans, with an additional beam and/or objectives penalizing protons stopping in OARs, were created to investigate the potential reduction of LETd, DRBE and NTCP.Results: The two variable RBE models agreed well and predicted average RBE values around 1.3 in the toxicity volumes, resulting in increased near-maximum DRBE of 7-11 Gy (RBE) compared to RBE=1.1 in the nominal scenario. The corresponding NTCP estimates increased from 0.8%, 0.0% and 3.7% (RBE=1.1) to 15.5%, 1.8% and 45.7% (Wedenberg RBE model) for the three patients, respectively. The MFO plans generally allowed for LETd, DRBE and NTCP reductions in OARs, without compromising the target dose. Compared to the clinical SFO plans, the maximum reduction of the near-maximum LETd was 56%, 63% and 72% in the OAR exhibiting the toxicity for the three patients, respectively.Conclusions: Although a direct causality between RBE and toxicity cannot be established here, high LETd and DRBE correlated spatially with the observed toxicities, whereas setup and range uncertainties had a minor impact. Individual factors, which might affect the patient-specific radiosensitivity, were however not included in these calculations. The MFO plans using both an additional beam and proton track-end objectives allowed the largest reductions in LETd, DRBE and NTCP, and might be future tools for similar cases.

Ämnesord

NATURVETENSKAP  -- Fysik -- Annan fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Other Physics Topics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Nyckelord

proton therapy
relative biological effectiveness
radiation-induced toxicity
Medical Radiation Physics
medicinsk strålningsfysik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.