SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:su-226992"
 

Sökning: id:"swepub:oai:DiVA.org:su-226992" > Design and performa...

Design and performance of the field cage for the XENONnT experiment

Antochi, Vasile C., 1992- (författare)
Stockholms universitet,Fysikum,Oskar Klein-centrum för kosmopartikelfysik (OKC)
Conrad, Jan, 1973- (författare)
Stockholms universitet,Fysikum,Oskar Klein-centrum för kosmopartikelfysik (OKC)
Rosso, Andrea Gallo, 1991- (författare)
Stockholms universitet,Fysikum,Oskar Klein-centrum för kosmopartikelfysik (OKC),Stockholm Univ, Oskar Klein Ctr, Dept Phys, AlbaNova, S-10691 Stockholm, Sweden
visa fler...
Joy, Ashley, 1988- (författare)
Stockholms universitet,Oskar Klein-centrum för kosmopartikelfysik (OKC),Fysikum
Mahlstedt, Jörn, 1985- (författare)
Stockholms universitet,Fysikum,Oskar Klein-centrum för kosmopartikelfysik (OKC)
Tan, Pueh-Leng, 1990- (författare)
Stockholms universitet,Fysikum,Oskar Klein-centrum för kosmopartikelfysik (OKC)
visa färre...
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: European Physical Journal C. - 1434-6044 .- 1434-6052. ; 84:2
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The precision in reconstructing events detected in a dual-phase time projection chamber depends on an homogeneous and well understood electric field within the liquid target. In the XENONnT TPC the field homogeneity is achieved through a double-array field cage, consisting of two nested arrays of field shaping rings connected by an easily accessible resistor chain. Rather than being connected to the gate electrode, the topmost field shaping ring is independently biased, adding a degree of freedom to tune the electric field during operation. Two-dimensional finite element simulations were used to optimize the field cage, as well as its operation. Simulation results were compared to 83mKr calibration data. This comparison indicates an accumulation of charge on the panels of the TPC which is constant over time, as no evolution of the reconstructed position distribution of events is observed. The simulated electric field was then used to correct the charge signal for the field dependence of the charge yield. This correction resolves the inconsistent measurement of the drift electron lifetime when using different calibrations sources and different field cage tuning voltages.

Ämnesord

NATURVETENSKAP  -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy