Sökning: id:"swepub:oai:DiVA.org:su-33986" >
Net Ecosystem Excha...
Net Ecosystem Exchange of Carbon Dioxide in a Temperate Poor Fen: A Comparison of Automated and Manual Chamber Techniques,
-
- Burrows, E.H. (författare)
- Univ New Hampshire
-
- Bubier, J.L. (författare)
- Mount Holyoke College
-
- Mosedale, A. (författare)
- Univ New Hampshire
-
visa fler...
-
- Cobb, G.W. (författare)
- Mount Holyoke College
-
- Crill, Patrick (författare)
- Stockholms universitet,Institutionen för geologi och geokemi
-
visa färre...
-
(creator_code:org_t)
- Springer Science and Business Media LLC, 2005
- 2005
- Engelska.
-
Ingår i: Biogeochemistry. - : Springer Science and Business Media LLC. - 0168-2563 .- 1573-515X. ; 76:1, s. 21-45
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- We used five analytical approaches to compare net ecosystem exchange (NEE) of carbon dioxide (CO2) from automated and manual static chambers in a peatland, and found the methods comparable. Once per week we sampled manually from 10 collars with a closed chamber system using a LiCor 6200 portable photosynthesis system, and simulated four photosynthetically active radiation (PAR) levels using shrouds. Ten automated chambers sampled CO2 flux every 3 h with a LiCor 6252 infrared gas analyzer. Results of the five comparisons showed (1) NEE measurements made from May to August, 2001 by the manual and automated chambers had similar ranges: -10.8 to 12.7 μmol CO 2 m-2 s-1 and -17.2 to 13.1 μmol CO 2 m-2 s-1, respectively. (2) When sorted into four PAR regimes and adjusted for temperature (respiration was measured under different temperature regimes), mean NEE did not differ significantly between the chambers (p < 0.05). (3) Chambers were not significantly different in regression of ln( - respiration) on temperature. (4) But differences were found in the PAR vs. NEE relationship with manual chambers providing higher maximum gross photosynthesis estimates (GPmax), and slower uptake of CO 2 at low PAR (α) even after temperature adjustment. (5) Due to the high variability in chamber characteristics, we developed an equation that includes foliar biomass, water table, temperature, and PAR, to more directly compare automated and manual NEE. Comparing fitted parameters did not identify new differences between the chambers. These complementary chamber techniques offer a unique opportunity to assess the variability and uncertainty in CO 2 flux measurements.
Ämnesord
- NATURVETENSKAP -- Geovetenskap och miljövetenskap (hsv//swe)
- NATURAL SCIENCES -- Earth and Related Environmental Sciences (hsv//eng)
Nyckelord
- Earth sciences
- Geovetenskap
- Biogeochemistry
- biogeokemi
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas