SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:su-79133"
 

Sökning: id:"swepub:oai:DiVA.org:su-79133" > Therapy optimizatio...

Therapy optimization based on non-linear uptake of PET tracers versus “linear dose painting”

Toma-Dasu, Iuliana (författare)
Stockholms universitet,Medicinsk strålningsfysik (tills m KI),Stockholm University and Karolinska Institutet
Uhrdin, Johan (författare)
RaySearch Laboratories AB, Stockholm, Sweden
Dasu, Alexandru (författare)
Umeå universitet,Radiofysik,Umeå University
visa fler...
Brahme, Anders (författare)
Karolinska Institutet, Sweden
visa färre...
 (creator_code:org_t)
Berlin, Heidelberg : Springer Berlin Heidelberg, 2009
2009
Engelska.
Ingår i: IFMBE Proceedings. - Berlin, Heidelberg : Springer Berlin Heidelberg. - 1680-0737 .- 1433-9277. ; 25/I, s. 221-224
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Treatment optimization based on positron emission tomography (PET) images of tumor hypoxia has been proposed as a method to improve the cure rates in radiotherapy through the increased dose delivery to tumor regions with increased radioresistance. One of the major advantages of PET imaging of hypoxia is that it can provide information on both the extent and the spatial distribution of the resistant regions. One of the key issues for the practical implementation of this approach is the accurate conversion of the intensities in the recorded images into radiosensitivity maps that could then be used for dose escalation. The present paper explores the influence of the conversion from uptake to prescribed doses. Transformation functions derived from the uptake properties of the PET tracers were taken into consideration. The results have shown that the available tracers have different uptake properties and therefore they could interpret differently the gradients in the images which in turn would lead to different dose predictions. Best results in terms of dose prescription would therefore be achieved by carefully taking into account the uptake characteristics of the imaged tracers. Linear approximations could lead to unnecessary overestimations of the doses for cases of partial hypoxia in tumors. This highlights the need for more experimental studies of the uptake properties of PET tracers proposed to image tissue hypoxia. These would eventually provide more reliable methods for dose prescription that could be used with optimization algorithms for the successful individualization of radiation therapy.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Nyckelord

hypoxia
treatment optimization
PET imaging
Radiation Physics
radiofysik
Medical Radiation Physics
medicinsk strålningsfysik
Oncology
onkologi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy