Comparison of a custom-made and a thermoplastic oral appliance for the treatment of mild sleep apnea

Vanderveken, Olivier M (författare)
Devolder, Annick (författare)
Umeå universitet,Ortodonti
Marklund, Marie (författare)
Umeå universitet,Institutionen för odontologi
visa fler...
Boudewyns, An N (författare)
Braem, Marc J (författare)
Okkerse, Walter (författare)
Verbraecken, Johan A (författare)
Franklin, Karl (författare)
Umeå universitet,Lungmedicin,Kirurgi
De Backer, Wilfried A (författare)
Van de Heyning, Paul H (författare)
visa färre...
 (creator_code:org_t)
New York : American Lung Association, 2008
2008
Engelska.
Ingår i: American Journal of Respiratory and Critical Care Medicine. - New York : American Lung Association. - 1073-449X .- 1535-4970. ; 178:2, s. 197-202
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Rationale: The efficacy of immediate adaptation of mandibular advancement devices made of thermoplastic material as a treatment option for sleep-disordered breathing (SDB) has been demonstrated in clinical studies. To date, there have been no studies comparing the efficacy of such prefabricated devices with custom-made devices. Objectives: Our purpose was to compare the efficacy of both types of devices in patients with SDB. Methods: A randomized controlled cross-over trial, comprising 4 months of treatment with a thermoplastic and a custom-made device, with a 1-month washout interval. Measurements and Main Results: A total of 35 patients (29 males; age, 49 ± 9 yr; apnea–hypopnea index [AHI], 13 ± 11 events/h; body mass index, 28 ± 4 kg/m2) completed the protocol. AHI was only reduced with the custom-madedevice (P = 0.005). In addition, this device reduced snoring to a greater extent than the thermoplastic device. The success rate was higher with the custom-made device (60 vs. 31%; P = 0.02). One-third of the patients demonstrated compliance failure with the thermoplastic device, mainly because of insufficient overnight retention. Total failure rate with the thermoplastic device was 69%, whereas the majority (63%) of these were successfully treated with the custom-made device. At the end of the study, 82% of the patients preferred the custom-made device, and 9% had no preference (P < 0.0001). Conclusions: In this study, a custom-made device turned out to be more effective than a thermoplastic device in the treatment of SDB. Our results suggest that the thermoplastic device cannot be recommended as a therapeutic option nor can it be used as a screening tool to find good candidates for mandibular advancement therapy.

Nyckelord

excessive somnolence
oral appliances
polysomnography
sleep apnea
snoring

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy