SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-121069"
 

Sökning: id:"swepub:oai:DiVA.org:umu-121069" > Dynamic PET simulat...

Dynamic PET simulator via tomographic emission projection for kinetic modeling and parametric image studies

Häggström, Ida (författare)
Umeå universitet,Radiofysik,Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA
Beattie, Bradley J (författare)
Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA
Schmidtlein, C Ross (författare)
Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA
 (creator_code:org_t)
2016-05-27
2016
Engelska.
Ingår i: Medical physics (Lancaster). - : American Association of Physicists in Medicine. - 0094-2405. ; 43:6, s. 3104-3116
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To develop and evaluate a fast and simple tool called dPETSTEP (Dynamic PET Simulator ofTracers via Emission Projection), for dynamic PET simulations as an alternative to Monte Carlo (MC), useful for educational purposes and evaluation of the effects of the clinical environment,postprocessing choices, etc., on dynamic and parametric images.Methods: The tool was developed in PETSTEP using both new and previously reported modules of PETSTEP (PET Simulator of Tracers via Emission Projection). Time activity curves are generated foreach voxel of the input parametric image, whereby effects of imaging system blurring, counting noise,scatters, randoms, and attenuation are simulated for each frame. Each frame is then reconstructed intoimages according to the user specified method, settings, and corrections. Reconstructed images werecompared to MC data, and simple Gaussian noised time activity curves (GAUSS).Results: dPETSTEP was 8000 times faster than MC. Dynamic images from dPETSTEP had a root meansquare error that was within 4% on average of that of MC images, whereas the GAUSS images werewithin 11%. The average bias in dPETSTEP and MC images was the same, while GAUSS differed by 3% points. Noise profiles in dPETSTEP images conformed well to MC images, confirmed visually by scatterplot histograms, and statistically by tumor region of interest histogram comparisons that showed nosignificant differences (p < 0.01). Compared to GAUSS, dPETSTEP images and noise properties agreedbetter with MC.Conclusions: The authors have developed a fast and easy one-stop solution for simulationsof dynamic PET and parametric images, and demonstrated that it generates both images andsubsequent parametric images with very similar noise properties to those of MC images, in afraction of the time. They believe dPETSTEP to be very useful for generating fast, simple, andrealistic results, however since it uses simple scatter and random models it may not be suitablefor studies investigating these phenomena. dPETSTEP can be downloaded free of cost from https://github.com/CRossSchmidtlein/dPETSTEP.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

dynamic PET
simulation
PETSTEP
Monte Carlo
compartment modeling
parametric imaging
radiofysik
radiation physics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Häggström, Ida
Beattie, Bradley ...
Schmidtlein, C R ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk bildbe ...
Artiklar i publikationen
Medical physics ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy