Cerebrospinal fluid infusion methods : development and validation on patients with idiopathic normal pressure hydrocephalus

Andersson, Nina, 1976- (författare)
Umeå universitet,Institutionen för strålningsvetenskaper
Eklund, Anders (preses)
Wårdell, Karin, Professor (opponent)
Medicinsk teknik, Linköping
 (creator_code:org_t)
Umeå : Umeå universitet, 2007
Engelska 74 s.
Serie: Umeå University medical dissertations, 0346-6612 ; 1116
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Cerebrospinal fluid (CSF) infusion tests can be used to estimate the dynamic properties of the CSF system. Idiopathic normal pressure hydrocephalus (INPH) is a syndrome signified by a disturbance to the CSF system, where the cause is unknown and the diagnosis is difficult to determine. As an aid in identifying patients with INPH who will improve after shunt surgery, infusion tests are commonly used to determine the outflow conductance (Cout), or outflow resistance (Rout=1/Cout), of the CSF system. The tests are also used to determine shunt function in vivo. The general aim of this thesis was to develop and validate CSF infusion methods, to investigate the dynamics of the CSF system. The methods should be applicable to patients with INPH, to aid in the quest to further improve the diagnosis and management of this syndrome.An existing mathematical model describing the dynamics of the CSF system was further developed. The characteristics of the model were verified and the effect of expanding intracranial air on the intracranial pressure (ICP) was simulated. The simulations supported the recommendation to maintain sea-level pressure during air ambulance transportation of patients with suspected intracranial air.A recently developed infusion apparatus was evaluated, on an experimental model as well as on a patient material. The repetitiveness in estimating Cout was found to be good. A statistically significant difference was found between the repeated Cout estimations in the patient group, indicating that there might have been a small physiological change introduced during the infusion test. A parameter, ∆Cout, was proposed and evaluated. It proved to reflect the reliability of individual Cout investigations in a clinically useful way, as well as to provide easily interpreted information.An adaptive algorithm for assessment of Cout was developed and evaluated on a patient group. The new algorithm was shown to reduce the investigation time, from 60 minutes, by 14.3 ± 5.9 minutes (mean ± SD), p<0.01, without reducing the reliability of the estimated Cout below clinically relevant levels.The relationship between ICP and CSF outflow was studied in a group of patients investigated for INPH. It was found that in the range of moderate increase from baseline pressure, the assumption of a pressure independent Rout was confirmed (p=0.5). However, at larger pressure increments, the relationship had a non-linear tendency (p<0.05). This indicates that the traditional view of a pressure independent Rout might have to be questioned in the region where ICP exceeds baseline pressure too much.Infusion tests can be performed in different ways, where three main categories may be distinguished. The bolus infusion method was compared to the constant pressure and constant flow infusion methods, on an experimental model as well as on a patient material. When physiological pressure fluctuations were added to the model, significant differences were found in the determination of Cout in the range of clinical importance, i.e. low Cout (p<0.05). The finding was supported by the patient investigations, the difference was however not significant.With the application of the new methods developed in this thesis, and the increased knowledge concerning relationships between CSF dynamic parameters, the CSF infusion test was further improved with the ability to increase measurement reliability in a reduced time. This constitutes a good basis to perform a large multi-centre study with the main goal to determine the predictive value of the parameter Cout.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

Infusion test
idiopathic normal pressure hydrocephalus
outflow conductance
outflow resistance
intracranial pressure
cerebrospinal fluid dynamics
medical informatics
medicinsk informatik

Publikations- och innehållstyp

vet (ämneskategori)
dok (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Andersson, Nina, ...
Eklund, Anders
Wårdell, Karin, ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
Delar i serien
Umeå University ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy