SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-14022"
 

Sökning: id:"swepub:oai:DiVA.org:umu-14022" > Class separation of...

Class separation of buildings with high and low prevalence of SBS by principal component analysis

Pommer, Linda (författare)
Umeå universitet,Kemiska institutionen
Fick, Jerker (författare)
Umeå universitet,Kemiska institutionen
Sundell, J (författare)
visa fler...
Nilsson, C (författare)
Sjöström, Michael (författare)
Umeå universitet,Kemiska institutionen
Stenberg, Berndt (författare)
Umeå universitet,Dermatologi och venereologi
Andersson, Barbro (författare)
Umeå universitet,Kemiska institutionen
visa färre...
 (creator_code:org_t)
2004-02-02
2004
Engelska.
Ingår i: Indoor Air. - : John Wiley & Sons. - 0905-6947 .- 1600-0668. ; 14:1, s. 16-23
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this study, we were able to separate buildings with high and low prevalence of sick building syndrome (SBS) using principal component analysis. The prevalence of SBS was defined by the presence of at least one typical skin, mucosal and general (headache and fatigue) symptom. Data from the Swedish Office Illness Study describing the presence and level of chemical compounds in outdoor, supply, and room air, respectively, were evaluated together with information about the buildings in six models. When all data were included the most complex model was able to separate 71% of the high prevalence buildings from the low prevalence buildings. The most important variable that separates the high prevalence buildings from the low prevalence buildings was a more frequent occurrence or a higher concentration of compounds with shorter retention time in the high prevalence buildings. Elevated relative humidity in supply and room air and higher levels of total volatile organic compounds in outdoor and supply air were more common in high prevalence buildings. Ten building variables also contributed to the separation of the two classes of low and high prevalence buildings.

Ämnesord

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Nyckelord

Principal component analysis
VOC
Sick building syndrome
Indoor air
Ventilation duct
Office building

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy