An experimental study on a novel radiant-convective heating system based on air source heat pump

Dong, Jiankai (författare)
Zhang, Long (författare)
Deng, Shiming (författare)
visa fler...
Yang, Bin (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik,Building Energy Efficiency
Huang, Shun (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2018
2018
Engelska.
Ingår i: Energy and Buildings. - : Elsevier BV. - 0378-7788 .- 1872-6178. ; 158, s. 812-821
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Air source heat pump (ASHP) has been widely applied to many parts of the world due to its simple structure and low initial cost. To save energy consumed for spacing heating and enhance the indoor thermal environment, improving the performances of ASHP has become one of the research focus in the relevant field. Currently, the most conventional heating terminal of ASHP system for spacing heating is finned tube heat exchanger coupled with air fan, which may cause strong draught sensation and dry eye problem and make users feel uncomfortable during convective heating. On the other hand, radiant heating is attracting more and more attention due to its comfortable indoor thermal environment. In this paper, a novel radiant-convective heating terminal was presented and coupled into an ASHP system. Both the operating characteristics and heating performances of the novel system were experimentally investigated. The experimental results showed that the novel system took about 28 min to enter a steady operating stage, during which the radiant panel surface temperature and outlet air temperature for the novel heating terminal, and COP of the novel system were 40.9 degrees C, 32.1 degrees C, and 3.11, respectively, under a standard heating condition. In addition, all parameters mentioned above saw a linear increase when the outdoor air temperature increased from -4.0 to 10.0 degrees C, and their respective rising rates were 0.41 degrees C, 0.28 degrees C and 0.04 per increased outdoor air temperature. Furthermore, the experimental results also demonstrated that adjusting the indoor air flow rate could effectively allocate the amount of heat generated by different heat transfer modes, which may have significant effects on the indoor thermal environment.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Nyckelord

Experimental study
Radiant heating
Convective heating
Air source heat pump

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Dong, Jiankai
Zhang, Long
Deng, Shiming
Yang, Bin
Huang, Shun
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
och Husbyggnad
Artiklar i publikationen
Energy and Build ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy