SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-148015"
 

Sökning: id:"swepub:oai:DiVA.org:umu-148015" > Patient-reported ou...

Patient-reported outcomes after sacrospinous fixation of vault prolapse with a suturing device : a retrospective national cohort study

Campbell, Jennifer (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för obstetrik och gynekologi,Institute of Clinical Sciences, Department of Obstetrics and Gynecology
Pedroletti, Corinne (författare)
Ekhed, Linn (författare)
visa fler...
Nüssler, Emil (författare)
Umeå universitet,Obstetrik och gynekologi,National Quality Register of Gynecological Surgery, Umeå, Sweden
Strandell, Annika, 1956 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för obstetrik och gynekologi,Institute of Clinical Sciences, Department of Obstetrics and Gynecology
visa färre...
 (creator_code:org_t)
2017-10-07
2018
Engelska.
Ingår i: International Urogynecology Journal. - : Springer. - 0937-3462 .- 1433-3023. ; 29:6, s. 821-829
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Introduction and hypothesis: Innovations in suturing devices have facilitated sacrospinous ligament fixation (SSF) for the correction of vaginal vault prolapse. It is uncertain if outcomes using suturing devices differ from those using a traditional suturing technique. We hypothesize that no difference exists in the efficacy and safety 1 year after SSF for vault prolapse performed with suturing devices or using a traditional technique. The objective was to compare SSF using a suturing device with traditional SSF for the treatment of vault prolapse, regarding symptoms of prolapse recurrence, patient satisfaction, incidence of re-operation, and complications 1 year postoperatively.Methods: We carried out a retrospective cohort study using register-based national data from 2006 to 2013. The Swedish Quality Register of Gynecological Surgery includes assessments pre-operatively, at hospital admittance, surgery, discharge, and questionnaires at 8 weeks and 1 year after surgery. Demographic variables and surgical methods were included in multivariate logistic regression analyses.Results: In the suturing device group (SDG, n = 353), 71.5% were asymptomatic of recurrence after 1 year compared with 78.7% in the traditional SSF group (TSG, n = 195); risk difference - 7.3% (95%CI -15.2%; 0.7%). Adjusted odds ratio (aOR) for being asymptomatic 1 year postoperatively was 0.56 (95%CI 0.31; 1.02, p = 0.057). Patient satisfaction was similar in SDG and TSG (78.1% vs 78.4%). Reoperation occurred in 7.4% in the SDG compared with 3.6% in the TSG, risk difference 3.8% (95%CI 0.0%; 7.5%), aOR 3.55 (95%CI 1.10; 11.44, p = 0.03).Conclusions: Patient satisfaction was similar 1 year after SSF, despite symptoms of recurrence being more likely and reoperation more common after using a suturing device compared with a traditional technique. The methods did not differ with regard to surgical complications.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Reproduktionsmedicin och gynekologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Obstetrics, Gynaecology and Reproductive Medicine (hsv//eng)

Nyckelord

patient-reported outcome
sacrospinous ligament fixation
suturing device
vault prolapse
Patient-reported outcome; Sacrospinous ligament fixation; Suturing device; Vault prolapse

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy