Sökning: id:"swepub:oai:DiVA.org:umu-149303" >
Amperometric biosen...
Amperometric biosensor for formic acid in air
-
- Sandström, K. J. Mattias (författare)
- Umeå universitet,Yrkesmedicin,Cranfield Biotechnology Centre, Cranfield University, UK; Department of Chemistry, National Institute for Working Life, Umeå, Sweden,Natl Institute Working Life, Department Chemistry, S-90713 Umea, Sweden; Umea University, Department Publ Hlth and Clin Med, S-90581 Umea, Sweden; Cranfield University, Cranfield Biotechnol Centre, Cranfield MK43 0AL, Beds, England;
-
- Newman, Jeffrey (författare)
- Cranfield Biotechnology Centre, Cranfield University, UK,Natl Institute Working Life, Department Chemistry, S-90713 Umea, Sweden; Umea University, Department Publ Hlth and Clin Med, S-90581 Umea, Sweden; Cranfield University, Cranfield Biotechnol Centre, Cranfield MK43 0AL, Beds, England;
-
- Sunesson, Anna-Lena (författare)
- Department of Chemistry, National Institute for Working Life, Umeå, Sweden,Natl Institute Working Life, Department Chemistry, S-90713 Umea, Sweden; Umea University, Department Publ Hlth and Clin Med, S-90581 Umea, Sweden; Cranfield University, Cranfield Biotechnol Centre, Cranfield MK43 0AL, Beds, England;
-
visa fler...
-
- Levin, Jan-Olof (författare)
- Umeå universitet,Yrkesmedicin,Department of Chemistry, National Institute for Working Life, Umeå, Sweden,Natl Institute Working Life, Department Chemistry, S-90713 Umea, Sweden; Umea University, Department Publ Hlth and Clin Med, S-90581 Umea, Sweden; Cranfield University, Cranfield Biotechnol Centre, Cranfield MK43 0AL, Beds, England;
-
- Turner, APF (författare)
- Cranfield Biotechnology Centre, Cranfield University, UK
-
visa färre...
-
(creator_code:org_t)
- Elsevier, 2000
- 2000
- Engelska.
-
Ingår i: Sensors and actuators. B, Chemical. - : Elsevier. - 0925-4005 .- 1873-3077. ; 70:1–3, s. 182-187
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- The possibility of developing a simple, inexpensive and specific personal passive “real-time” air sampler incorporating a biosensor for formic acid was investigated. The sensor is based on the enzymatic reaction between formic acid and formate dehydrogenase (FDH) with nicotinamide adenine dinucleotide (NAD+) as a co-factor and Meldola's blue as mediator. An effective way to immobilise the enzyme, co-factor and Meldola's blue on screen-printed, disposable, electrodes was found to be in a mixture of glycerol and phosphate buffer covered with a gas-permeable membrane. Steady-state current was reached after 4–15 min and the limit of detection was calculated to be below 1 mg/m3. However, the response decreased by 50% after storage at −15°C for 1 day.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Miljöbioteknik -- Annan miljöbioteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Environmental Biotechnology -- Other Environmental Biotechnology (hsv//eng)
Nyckelord
- Biosensor
- Air monitoring
- Formic acid
- Gas-permeable membrane
- Glycerol
- TECHNOLOGY
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas