SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-151567"
 

Sökning: id:"swepub:oai:DiVA.org:umu-151567" > A New Non-Enzymatic...

A New Non-Enzymatic Amperometric Sensor Based on Nickel Decorated ZIF-8 Derived Carbon Nanoframe for the Glucose Determination in Blood Samples

Sukhrobov, Parviz (författare)
Numonov, Sodik (författare)
Mamat, Xamxikamar (författare)
visa fler...
Li, Yongtao (författare)
Wågberg, Thomas, 1971- (författare)
Umeå universitet,Institutionen för fysik
Hu, Guangzhi (författare)
Umeå universitet,Institutionen för fysik,Key Laboratory of Chemistry of Plant Resources in Arid Regions, State Key Laboratory Basis of Xinjiang Indigenous Medicinal Plants Resource Utilization, Xinjiang Technical Institute of Physics
visa färre...
 (creator_code:org_t)
2018-07
2018
Engelska.
Ingår i: International Journal of Electrochemical Science. - : ESG. - 1452-3981. ; 13:7, s. 6550-6564
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The present study demonstrated a highly sensitive non-enzymatic glucose biosensor in real blood samples based on simple evaluated nickel deposited on N-doped porous carbon modified glassy carbon electrode (Ni/NPC/GCE) by applying electrochemical deposition method. The prepared material initially were characterized by cyclic voltammetry, the morphology structure of the as-prepared samples was observed by SEM, and composition, crystals structure of Ni/NPC were identified by SEM mapping and EDS tests. The Ni/NPC/GCE compared with NPC/GCE and NiNPs/GCE performed the best electrocatalytic behavior towards oxidation of glucose in 0.1 M KOH medium. By applied potential of +0.6 V Ni/NPC/GCE showed very high sensitivity of 3753.78 mu AmM(-1)cm(-2) in linear range of 1-7940 mu M with the correlation coefficient of R-2=0.995. The linear ranges get views above the concentration up to 7940 mu M with the detection limit of 0.3 mu M (S/N= 3). Amperometric time responses of prepared electrode towards different glucose concentrations are 0.8-1.3s. Finally, several positive characteristics such as very high sensitivity, weak working potential, nice anti-interference properties, long stability, good selectivity, and comparison with some other non-enzymatic sensors Ni/NPC/GCE executed high sensitivity, low detection limit and wide linear range to glucose sensing, thus the selected electrode is supplying for future glucose level determination design.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
NATURVETENSKAP  -- Fysik -- Den kondenserade materiens fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Condensed Matter Physics (hsv//eng)

Nyckelord

Nickel deposition
N-doped porous carbon
electrodeposition
glucose biosensor

Publikations- och innehållstyp

ref (ämneskategori)