SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-152420"
 

Sökning: id:"swepub:oai:DiVA.org:umu-152420" > Blood flow rate of ...

Blood flow rate of ophthalmic artery in patients with normal tension glaucoma and healthy controls

Kristiansen, Martin (författare)
Umeå universitet,Oftalmiatrik
Linden, Christina (författare)
Umeå universitet,Oftalmiatrik
Qvarlander, Sara (författare)
Umeå universitet,Radiofysik
visa fler...
Wåhlin, Anders (författare)
Umeå universitet,Radiofysik
Ambarki, Khalid (författare)
Umeå universitet,Radiofysik
Hallberg, Per (författare)
Umeå universitet,Radiofysik
Eklund, Anders, 1965- (författare)
Umeå universitet,Radiofysik
Jóhannesson, Gauti, 1979- (författare)
Umeå universitet,Oftalmiatrik
visa färre...
 (creator_code:org_t)
The Association for Research in Vision and Ophthalmology, 2018
2018
Engelska.
Ingår i: Investigative Ophthalmology and Visual Science. - : The Association for Research in Vision and Ophthalmology. - 0146-0404 .- 1552-5783. ; 59:9
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Purpose: To determine the blood flow rate of the ophthalmic artery (OA) in patients with Normal Tension Glaucoma (NTG) compared to age-matched healthy controls using phase-contrast magnetic resonance imaging (PCMRI).Methods: Seventeen patients with treated NTG (11 female; mean age: 70±9 years) and 16 age-matched healthy controls (10 female; mean age: 71±9 years) underwent PCMRI using a 3-Tesla scanner as well as ophthalmological examinations including visual acuity, Goldmann Applanation Tonometry, Humphrey perimetry and fundoscopy. Ophthalmic blood flow was acquired using a 2D PCMRI sequence set to a spatial resolution of 0.35mm/pixel. Mean flow rate and cross-sectional area was calculated using Segment Software. The eye with the most severe glaucomatous damage classified by visual field index (VFI) was chosen for comparison. The primary outcome was blood flow rate of OA.Results: The mean VFI was 41% ± 26 (mean±SD) for the worse NTG eyes. The intraocular pressure was 13.6±2.6 mmHg for NTG eyes and 13.8±2.1 mmHg for control eyes. The blood flow rate in the NTG group was 9.6±3.7 ml/min compared to 11.8±5.5 ml/min in the control group. The area was 1.7±0.3 mm2 and 2.0±0.6 mm2 respectively. No statistical significance was found between NTG and the control group regarding blood flow rate (p=0.07) or OA area (p=0.12).Conclusions: Despite OA being an anastomosis between the intracranial and extracranial circulation, possibly generating an eye unrelated variability in blood flow, we found a trend level reduction of approximately 2 ml/min in NTG. The finding warrants blood flow rate analysis of smaller arteries specifically supplying the eye, e.g. the central retinal artery.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Publikations- och innehållstyp

vet (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy