Evaluation of a routine hematology analyzer for quality control of leukoreduced plasma

Petersson, Annika (författare)
Ekblom, Kim, 1970- (författare)
Umeå universitet,Klinisk kemi,Department of Research and Development, Region Kronoberg, Växjö
 (creator_code:org_t)
2019-08-09
2019
Engelska.
Ingår i: Transfusion. - : Wiley. - 0041-1132 .- 1537-2995. ; 9:10, s. 3214-3218
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Quality control of residual white blood cells (WBCs) and red blood cells (RBCs) in leukoreduced plasma is mandatory. Although technological advances have been made, analysis of quality controls using routine hematology analyzers has not generally been introduced. The aim of this study was to evaluate if the routine hematology analyzer Sysmex XN‐10, (Sysmex Nordic ApS) could be used for quality control of residual WBCs and RBCs in leukoreduced plasma.STUDY DESIGN AND METHODS: Linearity, accuracy, and precision were established for two Sysmex XN‐10 analyzers using spiked donor plasma. ADAM rWBC (NanoEnTek) and manual counting in the Bürker chamber (NanoEnTek) were reference methods for WBCs and RBCs, respectively. Twenty‐five consecutive leukoreduced donor plasma samples were also tested.RESULTS: For WBCs, the linearity criteria were met for the ADAM rWBC, but not for the Sysmex XN‐10 instruments. Precision on both Sysmex XN‐10 instruments was accurate only at 6 cells/μL, and accuracy was consistently acceptable only at 5 to 6 cells/μL. The precision and accuracy of the ADAM rWBC were acceptable at 2 to 6 cells/μL.For RBCs, both Sysmex XN‐10 instruments and manual counting in the Bürker chamber were linear and fulfilled the precision criteria. Accuracy was acceptable for both Sysmex instruments at 6 to 12 × 109 WBCs/L but fluctuated within the study's measuring range for the Bürker chamber.No false‐positive results were seen in the 25 consecutive donor plasma samples tested.CONCLUSION: For quality control purposes of leukoreduced plasma, the Sysmex XN‐10 analyzer is suitable for the enumeration of residual RBCs but not of residual WBCs.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Hematologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Hematology (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Petersson, Annik ...
Ekblom, Kim, 197 ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Hematologi
Artiklar i publikationen
Transfusion
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy