SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-165443"
 

Sökning: id:"swepub:oai:DiVA.org:umu-165443" > Inter-sonographer r...

Inter-sonographer reproducibility of carotid ultrasound plaque detection using Mannheim consensus in subclinical atherosclerosis

Nyman, Emma (författare)
Umeå universitet,Kardiologi
Vanoli, Davide (författare)
Umeå universitet,Kardiologi
Näslund, Ulf (författare)
Umeå universitet,Kardiologi
visa fler...
Grönlund, Christer (författare)
Umeå universitet,Radiofysik
visa färre...
 (creator_code:org_t)
2019-10-29
2020
Engelska.
Ingår i: Clinical Physiology and Functional Imaging. - : John Wiley & Sons. - 1475-0961 .- 1475-097X. ; 40:1, s. 46-51
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Aims: To determine the inter-sonographer reproducibility of carotid ultrasound plaque detection using Mannheim consensus in a subclinical population and evaluate associations related to the reproducibility.Methods and results: Bilateral ultrasound screening for carotid plaques defined by Mannheim consensus was performed on 106 subclinical participants. Two different sonographers scanned the same participant, and reproducibility of plaque detection was measured by Cohens kappa. Associations with reproducibility were evaluated by comparing wall, and plaque characteristics between subjects with plaques identified in one and both scans. In general, the inter-sonographer reproducibility of plaque detection was substantial with a kappa value of 0 center dot 70 (95% CI 0 center dot 60-0 center dot 80). Plaques detected in only one scan had significantly lower plaque area and plaque thickness (6 center dot 82 mm(2) and 1 center dot 45 mm) as compared to plaques detected in both scans (11 center dot 65 mm(2) and 1 center dot 96 mm, P<0 center dot 001).Conclusion: Minor carotid plaques contribute to decreased reproducibility as compared to large plaques when screening for subclinical atherosclerosis using Mannheim consensus. Using an alternative plaque definition based on plaque thickness >1.5 mm and plaque area >10 mm(2) could increase the reproducibility of plaque detection in subclinical atherosclerosis.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Nyckelord

carotid
inter-sonographer
plaque
reproducibility
subclinical
ultrasound

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Nyman, Emma
Vanoli, Davide
Näslund, Ulf
Grönlund, Christ ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Fysiologi
Artiklar i publikationen
Clinical Physiol ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy