Sökning: id:"swepub:oai:DiVA.org:umu-172085" >
Cold windows induce...
Cold windows induced airflow effects on the thermal environment for a large single-zone building
-
- Zhang, Ying (författare)
- Umeå universitet,Institutionen för tillämpad fysik och elektronik,School of Building Services Science and Engineering, Xi’an University of Architecture and Technology,Energy Efficiency
-
- Olofsson, Thomas, 1968- (författare)
- Umeå universitet,Institutionen för tillämpad fysik och elektronik,Energy Efficiency ; Arcum
-
- Nair, Gireesh (författare)
- Umeå universitet,Institutionen för tillämpad fysik och elektronik,Energy Efficiency
-
visa fler...
-
- Zhao, Chenbo (författare)
- School of Building Services Science and Engineering, Xi’an University of Architecture and Technology
-
- Yang, Bin (författare)
- Umeå universitet,Institutionen för tillämpad fysik och elektronik,School of Building Services Science and Engineering, Xi’an University of Architecture and Technology,Energy Efficiency ; Arcum
-
- Li, Angui (författare)
- Umeå universitet,Institutionen för tillämpad fysik och elektronik,School of Building Services Science and Engineering, Xi’an University of Architecture and Technology,,Energy Efficiency
-
visa färre...
-
(creator_code:org_t)
- 2020-06-30
- 2020
- Engelska.
-
Ingår i: 12<sup>th</sup> Nordic Symposium on Building Physics (NSB 2020). - : Les Ulis EDP Sciences.
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
https://umu.diva-por... (primary) (Raw object)
-
https://www.e3s-conf...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- With access to modern building technologies and HVAC-systems, it is possible to obtain low energy use and good thermal comfort for complex design, such as large building volumes. However, the situation is different for large single zone buildings with large volumes. They often have insufficient thermal comfort. The problem could be partially attributed to the unwanted airflows due to the cold surfaces, especially the windows. With increased knowledge of the airflow, it is possible to identify suitable renovation strategies in such buildings.In this work, we study a church building with mechanical air change system and floor heating. CFD-simulations with dynamic airflow was conducted based on building geometries and technical data. The validation was based on data from the ventilation control and the space-heating system.The results show how the window-to-wall ratios and the positions of windows affect the thermal comfort. It contributes with knowledge of advantages and disadvantages of different envelope design in the existing environment with floor heating
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Energiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Energy Engineering (hsv//eng)
- NATURVETENSKAP -- Fysik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences (hsv//eng)