SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-175671"
 

Sökning: id:"swepub:oai:DiVA.org:umu-175671" > Impact of breath sa...

Impact of breath sampling on exhaled carbon monoxide

Ghorbani, Ramin, 1981- (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik
Blomberg, Anders, 1961- (författare)
Umeå universitet,Lungmedicin
Schmidt, Florian M. (författare)
Umeå universitet,Institutionen för tillämpad fysik och elektronik
 (creator_code:org_t)
2020-10-05
2020
Engelska.
Ingår i: Journal of Breath Research. - : Institute of Physics Publishing (IOPP). - 1752-7155 .- 1752-7163. ; 14:4
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The influence of breath sampling on exhaled carbon monoxide (eCO) and related pulmonary gas exchange parameters is investigated in a study with 32 healthy non-smokers. Mid-infrared tunable diode laser absorption spectroscopy and well-controlled online sampling is used to precisely measure mouth- and nose-exhaled CO expirograms at exhalation flow rates (EFRs) of 250, 120 and 60 ml s−1, and for 10 s of breath-holding followed by exhalation at 120 ml s−1. A trumpet model with axial diffusion is employed to fit simulated exhalation profiles to the experimental expirograms, which provides equilibrium airway and alveolar CO concentrations and the average lung diffusing capacity in addition to end-tidal concentrations. For all breathing maneuvers, excellent agreement is found between mouth- and nose-exhaled end-tidal CO (ETCO), and the individual values for ETCO and alveolar diffusing capacity are consistent across maneuvers. The eCO parameters clearly show a dependence on EFR, where the lung diffusing capacity increases with EFR, while ETCO slightly decreases. End-tidal CO is largely independent of ambient air CO and alveolar diffusing capacity. While airway CO is slightly higher than, and correlates strongly with, ambient air CO, and there is a weak correlation with ETCO, the results point to negligible endogenous airway CO production in healthy subjects. An EFR of around 120 ml s−1 can be recommended for clinical eCO measurements. The employed method provides means to measure variations in endogenous CO, which can improve the interpretation of exhaled CO concentrations and the diagnostic value of eCO tests in clinical studies.Clinical trial registration number: 2017/306-31

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Lungmedicin och allergi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Respiratory Medicine and Allergy (hsv//eng)

Nyckelord

real-time breath gas analysis
carbon monoxide (CO)
laser absorption spectroscopy
pulmonary gas exchange model
breath sampling
healthy non-smoker baseline

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ghorbani, Ramin, ...
Blomberg, Anders ...
Schmidt, Florian ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk labora ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Fysiologi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Lungmedicin och ...
Artiklar i publikationen
Journal of Breat ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy