SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-175804"
 

Sökning: id:"swepub:oai:DiVA.org:umu-175804" > Pulse Width and Imp...

Pulse Width and Implantable Pulse Generator Longevity in Pallidal Deep Brain Stimulation for Dystonia : A Population-Based Comparative Effectiveness Study

Agren, Richard (författare)
Karolinska Institutet
Bartek, Jiri, Jr. (författare)
Karolinska Institutet
Johansson, Anders (författare)
Karolinska Institutet
visa fler...
Blomstedt, Patric (författare)
Umeå universitet,Klinisk neurovetenskap
Fytagoridis, Anders (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2020-07-15
2020
Engelska.
Ingår i: Stereotactic and Functional Neurosurgery. - : S. Karger. - 1011-6125 .- 1423-0372. ; 98:5, s. 331-336
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Introduction: A wide range of pulse widths (PWs) has been used in globus pallidus internus (GPi) deep brain stimulation (DBS) for dystonia. However, no specific PW has demonstrated clinical superiority, and the paradigm may differ among DBS centers.Objective: To investigate how different paradigms of PWs in GPi DBS for dystonia affect implantable pulse generator (IPG) longevities and energy consumption.Methods: Thirty-nine patients with dystonia treated with bilateral GPi DBS at 2 Swedish DBS centers from 2005 to 2015 were included. Different PW paradigms were used at the 2 centers, 60–90 µs (short PWs) and 450 µs (long PW), respectively. The frequency of IPG replacements, pulse effective voltage (PEV), IPG model, pre-/postoperative imaging, and clinical outcome based on the clinical global impression (CGI) scale were collected from the medical charts and compared between the 2 groups.Results: The average IPG longevity was extended for the short PWs (1,129 ± 50 days) compared to the long PW (925 ± 32 days; χ2 = 12.31, p = 0.0005, log-rank test). IPG longevity correlated inversely with PEV (Pearson’s r = –0.667, p < 0.0001). IPG longevities did not differ between Kinetra® and Activa® PC in the short (p = 0.319) or long PW group (p = 0.858). Electrode distances to the central sensorimotor region of the GPi did not differ between the short or long PW groups (p = 0.595). Pre- and postoperative CGI did not differ between groups.Conclusions: Short PWs were associated with decreased energy consumption and increased IPG longevity. These effects were not dependent on the IPG model or the anatomic location of the electrodes. PWs did not correlate with symptom severities or clinical outcomes. The results suggest that the use of short PWs might be more energy efficient and could therefore be preferred initially when programming patients with GPi DBS for dystonia.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk apparatteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Equipment Engineering (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Neurovetenskaper (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Neurosciences (hsv//eng)

Nyckelord

Deep brain stimulation
Globus pallidus internus
Dystonia
Pulse generator longevity
Pulse width

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy