SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-176274"
 

Sökning: id:"swepub:oai:DiVA.org:umu-176274" > Sensitivity analysi...

Sensitivity analysis of different quality assurance methods for magnetic resonance imaging in radiotherapy

Adjeiwaah, Mary, 1980- (författare)
Umeå universitet,Radiofysik
Garpebring, Anders (författare)
Umeå universitet,Radiofysik
Nyholm, Tufve (författare)
Umeå universitet,Radiofysik
 (creator_code:org_t)
Elsevier, 2020
2020
Engelska.
Ingår i: Physics and Imaging in Radiation Oncology. - : Elsevier. - 2405-6316. ; 13, s. 21-27
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background and purpose: There are currently no standard quality assurance (QA) methods for magnetic resonance imaging (MRI) in radiotherapy (RT). This work was aimed at evaluating the ability of two QA protocols to detect common events that affect quality of MR images under RT settings.Materials and methods: The American College of Radiology (ACR) MRI QA phantom was repeatedly scanned using a flexible coil and action limits for key image quality parameters were derived. Using an exploratory survey, issues that reduce MR image quality were identified. The most commonly occurring events were introduced as provocations to produce MR images with degraded quality. From these images, detection sensitivities of the ACR MRI QA protocol and a commercial geometric accuracy phantom were determined.Results: Machine-specific action limits for key image quality parameters set at mean±3σ" role="presentation" style="box-sizing: border-box; margin: 0px; padding: 0px; display: inline-block; line-height: normal; font-size: 16.2px; word-spacing: normal; overflow-wrap: normal; white-space: nowrap; float: none; direction: ltr; max-width: none; max-height: none; min-width: 0px; min-height: 0px; border: 0px; position: relative;">mean±3σ were comparable with the ACR acceptable values. For the geometric accuracy phantom, provocations from uncorrected gradient nonlinearity effects and a piece of metal in the bore of the scanner resulted in worst distortions of 22.2 mm and 3.4 mm, respectively. The ACR phantom was sensitive to uncorrected signal variations, electric interference and a piece of metal in the bore of the scanner but could not adequately detect individual coil element failures.Conclusions: The ACR MRI QA phantom combined with the large field-of-view commercial geometric accuracy phantom were generally sensitive in identifying some common MR image quality issues. The two protocols when combined may provide a tool to monitor the performance of MRI systems in the radiotherapy environment.

Ämnesord

NATURVETENSKAP  -- Fysik -- Annan fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Other Physics Topics (hsv//eng)

Nyckelord

MRI in R
TQuality assurance
ACR
Image quality
Sensitivity analysis
Large geometric accuracy phantom
radiofysik
radiation physics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Adjeiwaah, Mary, ...
Garpebring, Ande ...
Nyholm, Tufve
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
och Annan fysik
Artiklar i publikationen
Physics and Imag ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy