SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:umu-178694"
 

Sökning: id:"swepub:oai:DiVA.org:umu-178694" > Breathing resistanc...

Breathing resistance in heat and moisture exchanging devices

Ainegren, Mats, 1963- (författare)
Mittuniversitetet,Institutionen för kvalitets- och maskinteknik,Sports Tech Research Centre
Hanstock, Helen, 1989- (författare)
Mittuniversitetet,Institutionen för hälsovetenskaper (HOV),Swedish Winter Sports Research Centre
Stenfors, Nikolai (författare)
Umeå universitet,Avdelningen för medicin,Umeå Universitet
 (creator_code:org_t)
2020-12-15
2022
Engelska.
Ingår i: Proceedings of the Institution of Mechanical Engineers, Part P. - : Sage Publications. - 1754-3371. ; 236:2, s. 97-105
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The purpose of this study was to investigate the resistance to breathing (RES) in heat and moisture exchanging devices (HME) intended for use during physical activity in the cold. RES was investigated for seventeen HMEs, including different types of filters. In addition, the influence of headwind on RES was tested using four representative HMEs. HMEs were mounted to the face of an artificial head manufactured from ABS plastic. The HMEs were connected to a mechanical lung simulator, which delivered standardised inspiratory and expiratory air flow rates (V⋅, L/s). The delta pressure (Δp, Pa) between ambient air and the air inside the HME was measured, whereupon RES was calculated. The results showed significant (p < 0.05) differences in RES between HMEs from different manufacturers, while the difference was smaller, and in some cases not significant (p > 0.05), between different models/filters within the same brand. The results also showed that RES was highly influenced by different ventilations and headwind conditions. RES increased with increased V⋅ and, when a headwind was introduced, RES decreased during inspiration and increased during expiration. Calculations showed that the oxygen and energy cost for breathing through an HME was very small for most of the tested models. The effect of HME dead space on pulmonary gas fractions depends on the tidal volume. At large tidal volumes and ventilations, the effect of HMEs on pulmonary gas fractions becomes relatively small.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Nyckelord

Asthma
breathing resistance
dead space
energy cost
face mask
headwind
ventilation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ainegren, Mats, ...
Hanstock, Helen, ...
Stenfors, Nikola ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Fysiologi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
Artiklar i publikationen
Proceedings of t ...
Proceedings of t ...
Av lärosätet
Umeå universitet
Mittuniversitetet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy